Resolved Caveats
This section describes the caveats that have been resolved in Cisco IOS Release 12.2(44)SE:
•
•
OL-14761-01
CSCsc96474
The switch might display tracebacks similar to these examples when a large number of IEEE 802.1x
supplicants try to repeatedly log in and log out.
Examples:
Jan 3 17:54:32 L3A3 307: Jan 3 18:04:13.459: %SM-4-BADEVENT: Event 'eapReq' is invalid
for the current state 'auth_bend_idle': dot1x_auth_bend Fa9
Jan 3 17:54:32 L3A3 308: -Traceback= B37A84 18DAB0 2FF6C0 2FF260 8F2B64 8E912C Jan 3
19:06:13 L3A3 309: Jan 3 19:15:54.720: %SM-4-BADEVENT: Event 'eapReq_no_reAuthMax' is
invalid for the current ate 'auth_restart': dot1x_auth Fa4
Jan 3 19:06:13 L3A3 310: -Traceback= B37A84 18DAB0 3046F4 302C80 303228 8F2B64 8E912C
Jan 3 20:41:44 L3A3 315: .Jan 3 20:51:26.249: %SM-4-BADEVENT: Event 'eapSuccess' is
invalid for the current state 'auth_restart': dot1x_auth Fa9
Jan 3 20:41:44 L3A3 316: -Traceback= B37A84 18DAB0 304648 302C80 303228 8F2B64 8E912C
There is no workaround.
CSCsd03580
When IEEE 802.1x is globally disabled on the switch by using the no dot1x system-auth-control
global configuration command, some interface level configuration commands, including the dot1x
timeout and dot1x mac-auth-bypass commands, become unavailable.
The workaround is to enable the dot1x system-auth-control global configuration command before
attempting to configure interface level IEEE 802.1x parameters.
CSCsj74022
The switch does not correctly update the entPhysicalChildIndex objects from the ENTITY-MIB, and
some of the entPhysicalChildIndex entries are missing from the table. This adversely affects
network management applications such as CiscoWorks CiscoView because they cannot manage the
switch.
There is no workaround.
CSCsm08603
This traceback error appears when you enter the show aaa subscriber profile privileged EXEC
command:
*Mar 2 01:50:41.127: %PARSER-3-BADSUBCMD: Unrecognized subcommand 10 in exec command
'show aaa subscriber profile WORD'
-Traceback= D003B4 D00AC8 C908A0 C2F040 C8CA18 CB8984 93B670 932338
There is no workaround. This does not affect switch functionality.
CSCeg67844
The switch no longer returns an incorrect value for the ciscoFlashPartitionFileCount MIB.
CSCei63394
Syslog messages are no longer generated when two or more IEEE 802.1x-capable hosts are
connected through a hub and the port is in single-host mode.
Release Notes for the Cisco Catalyst Blade Switch 3020 for HP, Cisco IOS Release 12.2(44)SE
Resolved Caveats
15