Sony XCL-CG510C Panduan Teknis - Halaman 25
Jelajahi secara online atau unduh pdf Panduan Teknis untuk Kamera Digital Sony XCL-CG510C. Sony XCL-CG510C 48 halaman. Digital video camera module
Trigger range limit
Only signals in the set trigger width can be accepted as the trigger signal. This functions as a noise filter, which removes
chattering or disturbance noise in the trigger signal line. This also functions as a trigger selector, whereby only a specific
camera can be operated by the trigger when multiple cameras share one trigger signal line. When the trigger signal is
input, exposure is started after the latency as per trigger range settings. If the trigger width is out of the range, video is
not output. If the trigger source is a soft trigger, trigger range limitation is not enabled.
Command
TRG-RANGE
TRG-RANGE-LOWER
Trigger range operation example
EXP=300, TRG-RANGE-LOWER=100 in the figure.
Trigger signal
Exposure
Sensor output
Image sensor Fast trigger mode
If the mode is set to OFF, the next exposure can be started even while reading images from the sensor. The exposure
will be started after approximately 2 line hours later from trigger signal detection.
If the mode is set to ON, the exposure will start immediately upon the trigger detection. The next exposure cannot be
started while reading images.
Command
Parameter
TRG-FAST
0
1
Frame Rate
Auto frame rate
The reading cycle is set to allow the frame rate to be the maximum value automatically according to the current shutter
setting and the partial scan setting in the free-run operation (Shutter has priority). The next exposure is performed while
outputting a video and the next video output is started immediately after finishing all video outputs. The frame rate is
lowered when setting the shutter time longer than the video output time.
Command
FRAMERATE-AUTO
Parameter
0
Trigger range off
1
Trigger range on
1 to 2000000
Trigger range lower limit [µs]
100 µs
Setting
Off
On
Parameter
Setting
0
Off
1
On
Setting