Frame Counter

You can read out the number of frames captured by the camera.
The counter can be reset.
Feature
FrameCounter
FrameCounterReset

Timing Chart

Trigger latency/Exposure time

The values of trigger latency (time from trigger acceptance to exposure start) and exposure time are as follows.
Trigger signal
Exposure
Sensor output
Feature
TriggerFastMode
False (0)
True (1)
The variation in trigger latency and exposure time varies depending on the output mode setting.
Exposure time
Trigger latency
Parameter
Trigger latency
Approx. 8 µs to approx. 82 µs
Approx. 0.2 µs
Exposure time
ExposureTime ± (approx. 0 µs to 27 µs)
ExposureTime ± (approx. 0 µs to 13 µs)