Sony XCU-CG160 Panduan Teknis - Halaman 25

Jelajahi secara online atau unduh pdf Panduan Teknis untuk Kamera Digital Sony XCU-CG160. Sony XCU-CG160 45 halaman. Digital video camera module

Sony XCU-CG160 Panduan Teknis

LUT

Five types of presets are provided. Specify using a 12-bit
value. Binarization, 5-point interpolation, and arbitrary
setting can be changed.
Feature
Parameter
LUTEnable
False (0)
True (1)
LUTFormat
Linear (0)
Reverse (1)

Binarization (2)

LinearInterpolation
(3)
UserSet (4)
Linear (γ=1)
5-point

Arbitrary setting

interpolation
Binarization
The binarization threshold can be changed.
Feature
BinarizationThreshold 0 to 2047 to 4095

5-point interpolation

The values of output points 1 through 5 that correspond
to input points 1 through 5 can be changed. Linear
interpolation is performed between interpolation points.
Feature
LinearInterpolationIndex
LinearInterpolationInValue
LinearInterpolationOutValue 0 to 4095
LinearInterpolationBuild
Setting
LUT off (g=1)
LUT on
Linear (γ=1)
Reverse
Binarization
5-point interpolation
Arbitrary setting
Reverse
Binarization
Parameter
Parameter
Setting
Index1 to
Select the
Index5
interpolation
points
0 to 4095
Input
Output
Build LUT
Setting example:
Output
LinearInterpolationIndex = Index1
LinearInterpolationInValue = 240
LinearInterpolationOutValue = 200
LinearInterpolationIndex = Index2
LinearInterpolationInValue = 900
LinearInterpolationOutValue = 400
LinearInterpolationIndex = Index3
LinearInterpolationInValue = 2047
LinearInterpolationOutValue = 3000
LinearInterpolationIndex = Index4
LinearInterpolationInValue = 3000
LinearInterpolationOutValue = 3200
LinearInterpolationIndex = Index5
LinearInterpolationInValue = 3800
LinearInterpolationOutValue = 3900
LinearInterpolationBuild
Arbitrary setting
The output values 0 through 4095 that correspond to
input values 0 through 4095 can be changed.
Feature
Parameter
LUTIndex
0 to 4095
LUTValue
0 to 4095
Setting example:
LUTIndex = 0
LUTValue = 3
LUTIndex = 1
LUTValue = 10
...
LUTIndex = 4094
LUTValue = 4000
LUTIndex = 4095
LUTValue = 4010
25
Input
Setting
Input
Output