Power Requirements

2400W Power Shelf LED Indicators
The 2400W AC-input power shelf includes three LEDs that are located on the front of each power
module for the 2400W AC-input power shelf. (See
Figure 1-13 2400W AC-Input Power Module LEDs
The power module LEDs for the enhanced AC-input power shelf are summarized in
Table 1-13 2400W AC-Input Power Module LEDs
LED
AC OK
DC OK
FAULT
Power Requirements
The Cisco AS5850 ships configured for either AC-input or DC-input power with loadsharing, depending
on your order.
AC-Input Power Specifications
The Cisco AS5850 accepts AC-input power using a separate, self-contained AC-input power shelf,
which converts AC-input power into DC output for use by the universal gateway. The AC-input power
shelf is rack-mounted and has a safety cover that shields the electrical connections in the power shelf
rear.
The AC-input to DC-output connection supplies –48 VDC-output power to the PEMFs. Power flows
through the filter module to the backplane, where it is distributed to the RSC and feature cards.
Cisco AS5850 Universal Gateway Hardware Installation Guide
1-28
DC OK AC OK FAULT
DC OK AC OK FAULT
DC OK AC OK FAULT
DC OK AC OK FAUL T
Color
Description
Green
On indicates power is present and within the specified voltage and
frequency levels.
Green
On indicates power is present and within the specified voltage and
frequency levels.
Red
On indicates a power fault condition such as overvoltage, undervoltage,
overtemperature, or HV bus low.