Cisco Cisco mds 9216 - fabric switch Panduan Pemasangan Perangkat Keras - Halaman 23

Jelajahi secara online atau unduh pdf Panduan Pemasangan Perangkat Keras untuk Perangkat Keras Jaringan Cisco Cisco mds 9216 - fabric switch. Cisco Cisco mds 9216 - fabric switch 36 halaman. Multilayer fabric switch
Juga untuk Cisco Cisco mds 9216 - fabric switch: Manual Koneksi (13 halaman), Panduan Konfigurasi (49 halaman), Catatan Rilis (48 halaman), Catatan Rilis (44 halaman), Catatan Rilis (44 halaman), Catatan Rilis (36 halaman), Catatan Rilis (26 halaman), Catatan Rilis (22 halaman), Panduan Referensi Cepat (14 halaman), Catatan Rilis (3 halaman), Spesifikasi (11 halaman)

Cisco Cisco mds 9216 - fabric switch Panduan Pemasangan Perangkat Keras
Chapter 2
Installing the Cisco MDS 9216 Switch
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m .
Caution
After the switch boots, verify that the LED behavior is as follows:
Step 8
Note
If any LEDs are orange (except on the CSM) or red after the initial boot processes are complete, see
Appendix B, "Troubleshooting."
Try removing and re-installing a component that is not operating correctly. If it still does not operate
Step 9
correctly, contact your customer service representative for a replacement.
Note
Verify that the system software has booted and the switch has initialized without error messages. If any
Step 10
problems occur, refer to
for the latest Cisco MDS 9000 Family Troubleshooting Guide or the Cisco MDS 9000 Family System
Messages Guide. If you cannot resolve an issue, contact your customer service representative.
Complete the worksheets provided in
Step 11
reference.
OL-6985-01
Do not operate the switch without a functioning fan module except for during the brief fan
module replacement procedure. The Cisco MDS 9000 Family switches can operate for only a
few minutes without any functioning fan modules before they begin to overheat.
Fan module: Status LED is green
Power supplies:
Input Ok LED is green.
Fan Ok LED is green.
Output Fail LED is off.
Supervisor, switching, or services modules:
During initialization, the status LED on the module flashes orange once, remains orange during
diagnostic boot tests, then turns green when the module is operational (online). If the system
software is unable to start up, this LED remains orange or turns red.
After initialization, the status LED is green, indicating that all chassis environmental monitors
are reporting that the system is operational. If this LED is orange or red, then one or more
environmental monitor is reporting a problem.
Ethernet port Link LEDs should not be on unless the cable is connected.
The link LEDs for the Fibre Channel ports remain yellow until the ports are enabled, and the
LED for the MGMT 10/100 Ethernet port remains off until the port is connected.
If you purchased this product through a Cisco reseller, contact the reseller directly for technical
support. If you purchased this product directly from Cisco, contact Cisco Technical Support at
this URL: http://www.cisco.com/warp/public/687/Directory/DirTAC.shtml.
http://www.cisco.com/univercd/cc/td/doc/product/sn5000/mds9000/index.htm
Appendix E, "Site Planning and Maintenance Records"
Cisco MDS 9216 Switch Hardware Installation Guide
Starting Up the Switch
for future
2-23