Cisco Firepower 4150 Manual - Halaman 8

Jelajahi secara online atau unduh pdf Manual untuk Perangkat Keras Jaringan Cisco Firepower 4150. Cisco Firepower 4150 26 halaman. Rack-mount and ground the chassis
Juga untuk Cisco Firepower 4150: Panduan Pemeliharaan dan Peningkatan (20 halaman), Manual (36 halaman), Manual (8 halaman), Manual (42 halaman), Memulai (42 halaman)

Cisco Firepower 4150 Manual
Remove and Replace the SSD
Warning
Step 1
Save your configuration.
Step 2
Power down the chassis by moving the power switch to the OFF position. See
power switch.
Step 3
To remove an SSD, face the front of the chassis, loosen the two captive screws on the SSD, and gently pull it out of slot
1 of the chassis.
Figure 3: Remove the SSD
Step 4
To replace the SSD, make sure the power switch is still in the OFF position, and then hold the SSD in front of slot 1 and
push it in gently until it is seated.
Step 5
To install the MSP SSD, make sure the power switch is still in the OFF position and then remove the blank faceplate in
slot 2 by loosening the captive screws on either side of the faceplate.
Step 6
Hold the MSP SSD in front of slot 2 and push it in gently until it is seated.
Do not switch the two SSDs. Only the optional MSP SSD can be installed in slot 2. If you remove it and install
Caution
it in slot 1, all stored file capture data is lost.
Step 7
Tighten the captive screws on either side of the SSD.
Step 8
Verify that the SSD is operational by checking the SSD LED. See
Installation, Maintenance, and Upgrade
8
Statement 1091 Installation by an Instructed Person
Only an instructed person or skilled person should be allowed to install, replace, or service this equipment.
See statement 1089 for the definition of an instructed or skilled person.
Installation, Maintenance, and Upgrade
Features
for more information about the
Front Panel LEDs
for a description of the fan LEDs.