Cisco Performance Routing Engine 5 Panduan Pemasangan Perangkat Keras - Halaman 28
Jelajahi secara online atau unduh pdf Panduan Pemasangan Perangkat Keras untuk Perangkat Keras Jaringan Cisco Performance Routing Engine 5. Cisco Performance Routing Engine 5 35 halaman.
Juga untuk Cisco Performance Routing Engine 5: Panduan Memulai Cepat (2 halaman)
Temperature Sensor
FP Outlet1 sensor
FP Outlet2 sensor
COBALT sensor
Setting the Automatic Shutdown Command
• The auto-shutdown disabled command controls the automatic shutdown action when the critical temperature is exceeded..
• To enable or disable the auto-shutdown when the critical temperature threshold exceeded for 2 minutes:
facility-alarm [core-temperature | intake-temperature] critical exceed-action shutdown
• To set the temperature thresholds at which the Cisco uBR100012 router generates a major or minor alarm, or to disable those
alarms, use
facility-alarm {intake-temperature | core-temperature} {critical exceed-action shutdown | major [temp] | minor [temp] }
Note
Configure the facility-alarm outlet-temperature critical exceed-action value on the PRE5 to the desired setting when
upgrading to the PRE5 module.
Troubleshooting Examples for the PRE5 Module
Troubleshooting: Console Port Does not Work
You cannot enter any command on the PRE5 console.
Problem
Hardware or software flow control is enabled on the terminal connected to the PRE5 console port.
Possible Cause
Disable the hardware and software flow control on the terminal. For more information, see
Solution
Broadband Router Hardware Installation
Cisco PRE5 Module Part Numbers and Specifications
Part Numbers
Description
Performance Routing Engine 5 For Cisco uBR10012
Router, Base Hardware
Performance Routing Engine 5 For Cisco uBR10012
Router, Base Hardware Spare
10G license, Must Configure With PRE5 Only
1 count 10G license for PRE5
Board to board cable for PRE5 interconnection
28
Minor
87ºC/188ºF
87ºC/188ºF
90ºC/194ºF
Guide.
Part Number
UBR10-PRE5
UBR10-PRE5=
SWLIC-PRE5-10G
1 2
L-PRE5-10G
CAB-PRE5-BTB
Major
97ºC/206ºF
97ºC/206ºF
95ºC/203ºF
Critical
100ºC/212ºF
100ºC/212ºF
100ºC/212ºF
Cisco uBR10012 Universal
Minimum Cisco IOS
Release
12.2(33) SCH
12.2(33) SCH
12.2(33) SCH
12.2(33) SCH
12.2(33) SCH