AcueLighting Extreme 150 Hybrid Buku Petunjuk - Halaman 6
Jelajahi secara online atau unduh pdf Buku Petunjuk untuk Peralatan Pencahayaan AcueLighting Extreme 150 Hybrid. AcueLighting Extreme 150 Hybrid 11 halaman.
It must be ensured that an expert inspects the mechanical and safety-relevant installation prior to the initial
operation and following major modifications, prior to the renewed operation. It must be ensured that an expert
inspects the mechanical and safety-relevant installation at least once a year. It must be ensured that an expert
inspects the mechanical installation and the installation of relevance to safety within the framework of an
acceptance test at least every four years.
The installation method must be as such that it can withstand 10 times the load capacity without harmful
deformation for a period of 60 minutes.
The light effect unit must be secured by a safety cable if fly-mounted. The cable must withstand 12 times the
weight of the light effect unit. Use arrester cables equipped with quick closing links. The dropping distance must
not exceed 20 cm. Defect arrested cables or arrested cables that have already been exposed to stress must not be
used.
7.
Operation
7.1 Controls
Link all DMX devices with a DMX-512 controller by using a standard, 3-pin DMX cable or 5-pin DMX
cables. Connect the output of the first device with the input of the second device and the output of the second
device with the input of the third device and so on.
Connect the mains plug to an outlet.
Operating the product for the first time may generate smoke and odor; this is not a defect. Avoid
disconnecting the product repeatedly and quickly from mains. Always wait 15 minutes prior to the next
disconnection
7.2 Menu Structure
ATTENTION:
RISK OF HEALTH!
5