Cisco Firepower 2130 Instalasi & Pemeliharaan - Halaman 3

Jelajahi secara online atau unduh pdf Instalasi & Pemeliharaan untuk Server Cisco Firepower 2130. Cisco Firepower 2130 26 halaman. Rack-mount and ground the chassis
Juga untuk Cisco Firepower 2130: Manual (12 halaman), Panduan Penyebaran (8 halaman), Memulai (42 halaman)

Cisco Firepower 2130 Instalasi & Pemeliharaan
Installation, Maintenance, and Upgrade
Figure 1: Remove the Network Module
If the slot is to remain empty, install a blank faceplate to ensure proper airflow and to keep dust out of the chassis;
otherwise, install another network module.
Step 4
To replace a network module, hold the network module in front of the network module slot on the right of the chassis
and pull the network module handle out.
Step 5
Slide the network module into the slot and push it firmly into place until the handle is flush with the front of the network
module.
Step 6
Tighten the captive screw on the lower left side of the network module.
Step 7
Power on the chassis so that the new network module is recognized.

Remove and Replace the SSD

Although the hardware supports removing and replacing SSDs while the system is running, the software does
not currently support hot swapping. You must power down the chassis to remove and replace SSDs.
Note
Note
The 100-GB SSD is restricted to the 2110 and 2120. The 200-GB SSD is restricted to the 2130 and 2140. Do
not mix them.
We may ship larger capacity SSDs depending on component supply availability. The larger capacity SSDs
are formatted to 100-GB for the 2110 and 2120 and formatted to 200-GB for the 2130 and 2140.
Remove and Replace the SSD
Installation, Maintenance, and Upgrade
3