Cisco UCS B200 M3 Panduan Instalasi - Halaman 23

Jelajahi secara online atau unduh pdf Panduan Instalasi untuk Server Cisco UCS B200 M3. Cisco UCS B200 M3 34 halaman. Blade server
Juga untuk Cisco UCS B200 M3: Catatan Instalasi dan Layanan (36 halaman), Catatan Instalasi dan Layanan (37 halaman), Manual (8 halaman), Panduan Peningkatan (21 halaman), Catatan Instalasi dan Layanan (28 halaman)

Cisco UCS B200 M3 Panduan Instalasi
Procedure
Step 1
Open both DIMM connector latches.
Figure 18: Installing DIMMs in the Blade Server
Step 2
Press the DIMM into its slot evenly on both ends until it clicks into place.
DIMMs are keyed, if a gentle force is not sufficient, make sure the notch on the DIMM is correctly aligned.
Note
Be sure that the notch in the DIMM aligns with the slot. If the notch is misaligned you may damage the DIMM,
the slot, or both.
Step 3
Press the DIMM connector latches inward slightly to seat them fully.
Supported DIMMs
The DIMMs supported in this blade server are constantly being updated. A list of currently supported and available drives is in the
specification sheets at:
http://www.cisco.com/en/US/products/ps10280/products_data_sheets_list.html
Cisco does not support third-party memory DIMMs, and in some cases their use may irreparably damage the server and require an
RMA and down time.
23