Cisco UCS B460 M4 Panduan Memulai Cepat - Halaman 3

Jelajahi secara online atau unduh pdf Panduan Memulai Cepat untuk Server Cisco UCS B460 M4. Cisco UCS B460 M4 5 halaman. Blade server
Juga untuk Cisco UCS B460 M4: Lembar data (7 halaman), Catatan Instalasi dan Layanan (46 halaman), Panduan Memulai Cepat (2 halaman), Catatan Instalasi dan Layanan (50 halaman)

Cisco UCS B460 M4 Panduan Memulai Cepat
Package-Vers:
Update-Status: Ready
Activate-Status:
Startup-Vers:
Backup-Vers: 2.2(3b)
Bootloader-Vers: 2.2(3a).33
CIMC:
Running-Vers: 2.2(3b)
Package-Vers: 2.2(3b)B
Update-Status: Ready
Activate-Status: Ready
Startup-Vers: 2.2(3b)
Backup-Vers: 2.2(3b)
Bootloader-Vers: 2.2(3b).33
Solution
In order to recover from this, follow the steps below.
1) Navigate to Equipment > Chassis > Chassis # > Servers > Server # > Installed Firmware tab.
2) Right-click on the component that needs to be updated (e.g. BIOS, CIMC Controller) and select Update Firmware. In this example, the CIMC Controller
will be updated to 2.2(3b).
3) Select the correct firmware, the Force checkbox and click Apply.
Tip: If it's not clear which version needs to be selected from the dropdown, the network
administrator can navigate to Equipment > Firmware Management > Packages, expand
ucs-k9-bundle-b-series.VERSION.B.bin and look for "ucs-EXM4." There will be three
components: bios (BIOS), brdprog (Board Controller), and cimc (CIMC Controller).
4) Monitor the Installed Firmware tab and wait until the Update Status and Activate Status columns change to Ready and the Backup Version column