Vibrator
A particular feature of this newly developed vibrator is its
easily calibrated impact interval of from 0.5 to 200 impacts per
minute.
The impact force can be set to three levels.
Pneumatic impact force: Via the compressed air's exhaust
channel.
Upper exhaust channel open = maximum force
Lower exhaust channel open = minimum force
Pneumatic frequency:
The vibrator is supplied with a base plate, which serves to
attach it and to transmit the impacts it generates.
The vibrator's housing and base plate are made from
aluminium. The impact plate (integrated into the base plate) is
made from shock-resistant special plastic material.
Areas of application
Compressed air interval vibrators can be employed for knocking off material that has become attached to the inner surfaces of
containers (e.g. silos, hoppers, filter outlets, reactors and pipelines).
These vibrators can be used in wet surroundings and in those where there is a risk of explosion, or in the open air.
Construction and mode of operation
In the case of an FKL 100 mi, a piston is pushed against a spring by means of compressed air. Each time the piston passes the
compressed air outlet port, there is a rapid venting and it is shot under spring pressure against the impact plate contained within
the device. The piston valve then closes and the procedure is repeated at the speed set by means of the throttle.
Operating conditions
Reciprocating vibrators can be employed in dusty, wet or explosion-protected environments. Their piston seals are suitable for
oil free operation.
Standard installation for the FKL 100 mi
The drive mechanism is to be provided by the customer
Operation of the device can be controlled via a 3/2-way, normal/shut air valve. (Not to be confused with the interval, which is
set using the throttle valve supplied.) Hose of 6 mm diameter
The control mechanism can be by means of a:
Technical Data
Pressure
Device
bars
FKL 100 mi
6 - 8
The FKL 100 mi can be employed for wall thicknesses of up to 5 mm
1
Set impact force; Inlet 6 bars; Set frequency
Operating instructions for FKL 100 mi
4300.00
By means of a throttle valve
(included in supply specification)
Action / Impact
Nm
10 / 20 / 40
1
- Process control system
Impulse /
Impact
Ns
5 / 7.5 / 10
EM
- Time lag relay - On/off switch
Weight
Air consumption
kgs
litre / impact
4.45
0.5 – 1.1
02.07.2003
Frequency
impact / min.
0.5 - 200