Acuity Brands HOLOPHANE Utility Series Panduan Instalasi dan Pemeliharaan - Halaman 4
Jelajahi secara online atau unduh pdf Panduan Instalasi dan Pemeliharaan untuk Peralatan Pencahayaan Acuity Brands HOLOPHANE Utility Series. Acuity Brands HOLOPHANE Utility Series 8 halaman. Utility series led retrofit kit
Figure 1
Figure 2
TERMINAL
BLOCK
PHOTOCONTROL
RECEPTACLE
WIRE TIE
POLE FITTER
2.2 Luminaire LED Retrofit.
2.2.1
This retrofit kit is provided in three main parts: the electrical tray,
upper heat sink casting assembly and the reflector assembly.
2.2.2 Ensure that power is off to the pole and light
fixture.
It is recommended that the fixture to be retrofitted be
removed from its current mounting and taken to a place where the new
parts can be laid out, and where the existing fixture can be
disassembled easily. Place the fixture on a clean, dry, flat surface.
2.2.3
Wipe off exterior dirt and debris from the surfaces using a soft,
clean cloth.
GR1862
DRIVER
MODULE
SET SCREWS (6)
GR1862
CAUTION
DO NOT USE ABRASIVE CLEANSERS ON OPTICAL
SURFACES. THEIR USE MAY RESULT IN THE LOSS
OF OPTICAL EFFICIENCY.
2.2.4
Unlatch the top cover assembly and remove the hinge pin from
the hinge section. Place the top cover assembly to the side.
2.2.5
Reach inside the refractor housing and remove the glass or
plastic optic. It will be reused later so place it in an area where it won't
be damaged.
2.2.6
See Fig 1. Unlatch the door assembly and open it to expose the
ballast module. Remove the current ballast module and dispose of it in
a safe and proper manner. Also note the existing nameplate label;
remove this label from the product. There is a new nameplate attached
to the driver module. See Fig 2.
2.2.7
Check inside the ballast housing and note the position of the
black, green, and white leads connected to the terminal block and to
the 6 position Molex connector. Using a flat-end screwdriver, reach
inside the ballast chamber and remove the existing 6 position Molex
connector from the terminal block.
2.2.8
Connect the electrical supply wires from the shorter provided
harness to the terminal block in the back of the electrical chamber.
The terminals are marked "L1" (Line 1), "G" (Ground), and "L2" (Line
2). If one of the supply lines is electrically neutral, it should be
connected to terminal "L2". At the other end of the harness, connect
the quick-disconnect plastic connector with black, white, and green
wires to the corresponding connector on the driver module.
2.2.9
In the bottom of the optical compartment there are three hex
head bolts. Remove these bolts and remove the upper "cage" portion.
Remove the two screws holding the socket to the housing; discard this
socket.
2.2.10
Thread the harness provided through the opening provided
after the socket has been removed. Remove protective liner from the
gasket provided and seal around the harness.
Figure 3
GR1958
IM-431-A