Digiway P750L Buku Petunjuk - Halaman 5
Jelajahi secara online atau unduh pdf Buku Petunjuk untuk Pembuka Pintu Garasi Digiway P750L. Digiway P750L 13 halaman. Sliding gate motor
P750LV2.1 industrial gate motor manual
CONTROL INPUIT AND BUTTON
1.OPN open push button
2. CLS close push button
3. PED pedestrian open push button
4. STP stop push button
5. OSC open/stop/close push button
6. PEB photo electrical beams
7. Gate status display, open green, close red
8. Mode selection DIP switch
9. Motor protect fuse 5A and Transformer fuse 0.5A
10. Main inputs 240VAC.
11. Motor power input/inverter COM. input
12. Motor2 open and close outputs
13. Motor1 open and close outputs
14. Lock output
15. Motor2 limit switches
16. Motor1 limit switches
17. Limit switch input common +12VD/+12VDC @300MA output for the sensor
18. Control inputs
19. Set1 and Set2 DIP switch
2.2 Control inputs
2.2.1 Open (OPN) input & OPN push button
The OPN inputs are Push Button OPN and Terminal OPN input. Push OPN button and activating
(connect OPN terminal to the +12V) the OPN input will start to open the gate. When gate opened,
if OPN is keep activating, the gate will stay open. This is mostly controlled by access control
system.
2.2.2 Pedestrian Access (PED) input and Pedestrian (PED) push button
The pedestrian input partly opens the gate leaf driven by motor1 in the case of single speed mode,
or partly opens gate in the case of sliding gate mode. How far the gate will open depending on the
Pedestrian Open Time, this can be changed by user. If P.E input is activated during the gate is
closing, the gate will reopen for another Pedestrian Open Time. P.E Close setting and Auto Close
setting will also apply to pedestrian cycle.
2.2.3 Close Terminals input (CLS) and Close (CLS) Push button
The CLS terminals input is used to close the gate. Push button on control board is mainly used to
test when finished the installation. Pushing it will cause gate to close if the gate in the opened
position or in the opening cycle. If gate is in the closed or closing, the gate situation is not change.
2.2.4 STP stops input and stop button
STP input and STP button is used for stop the gate and settings
2.2.5 OSC (open/stop/close) input
OSC input and OSC button is used for manual operation. Push to open the gate, push again stop
gate, another push closes the gate.
2.2.6 Photoelectric safety beam (PE) input (N/C type)
If the P.E input is activated while gate is closing, the controller will stop the gate or reopen the
gate depending on the DIP setting. If the gate in the opened position and P.E beam is activated, the
gate will stay in opened
5