Acuity Brands Lighting Lithonia HLF2 Petunjuk Instalasi - Halaman 4

Jelajahi secara online atau unduh pdf Petunjuk Instalasi untuk Peralatan Pencahayaan Acuity Brands Lighting Lithonia HLF2. Acuity Brands Lighting Lithonia HLF2 5 halaman. Led area light

Acuity Brands Lighting Lithonia HLF2 Petunjuk Instalasi
Installation Instructions
HLF LED
IS (ships installed): Remove the access cover plate to the integral wiring compartment using a 1/4" hex socket or regular screwdriver. Slip
integral slipfitter onto tenon ensuring that the wires are pulled through the integral wiring compartment without pinching. Secure the slipfitter
to the tenon by tightening the 4 bolts to 20-25 ft-lbs. To adjust the tilt angle of the fixture, loosen the 5/16" hex socket screw above the integral
wiring compartment. Adjust as necessary and retighten. Make supply connections through the integral wiring compartment. Push wires into
compartment. Re-install the access cover plate.
HLF1 (integral slipfitter)
Attaching VNSP External Reflector:
1) Assemble the supplied indexing plate to the outer lens frames
using the (4) 8-32 screws. The lens frames have pre-drilled holes for
attachment.
3) Rotate assembly until the opposing tab aligns with the opposing
indexing plate slot. Push the assembly downward until the tab clicks.
2) Insert tab into slot on indexing bracket.
4) Assemble #8-32 screws in holes located on both sides of the as-
sembly (2x HLF1; 4x HLF2).
Lithonia Lighting Outdoor • One Lithonia Way • Conyers, Georgia 30012
Phone: 800-279-8041 • Fax: 770.918.1209 •
© 2012 Acuity Brands Lighting, Inc. All rights reserved. Rev. 3/13
HLF2 (integral slipfitter)
www.lithonia.com
Part Number: RJ521380 Rev B
Revision Date: 4-4-16