Crow MRX-220N Petunjuk Instalasi - Halaman 2

Jelajahi secara online atau unduh pdf Petunjuk Instalasi untuk Sensor Keamanan Crow MRX-220N. Crow MRX-220N 2 halaman.

11
FIG.4 - PCB LAYOUT
BLOCK
CONNECTOR
ANTENNA
DOPPLER
ALARM
LED
ROTARY
Tamper
SWITCH
Double Dual Pyrosensors on opposite side
2
BRACKET SCREW
Install part 1 to wall using 4 screws; connect part 2
to part 1, adjust the detector to required direction
and tighten the bracket screw
15
TEST PROCEDURES
Wait one-minute for warm-up time after applying
power.
Make the test at the protected area free of moving
.
people
LED should be in enable position.
Walk test
1. Start walking slowly across the detection zone.
2. Observe that the red LED lights whenever
motion is detected.
3. Allow 5 sec. between each test for the detector
to stabilize.
NOTE:
Walk tests should be done at least once a year to
confirm proper operation of the detector.
You must reset the detector from
Control Panel before the new
settings will take effect
18
CROW ELECTRONIC ENGINEERING LTD. ("Crow") –
WARRANTY POLICY CERTIFICATE
This Warranty Certificate is given in favor of the purchaser (hereunder the
"Purchaser") purchasing the products directly from Crow or from its authorized
distributor.
Crow warrants these products to be free from defects in materials and
workmanship under normal use and service for a period of 24 months from the
last day of the week and year whose numbers are printed on the printed circuit
board inside these products (hereunder the "Warranty Period").
Subject to the provisions of this Warranty Certificate, during the Warranty
Period, Crow undertakes, at its sole discretion and subject to Crow's
procedures, as such procedures are form time to time, to repair or replace, free
of charge for materials and/or labor, products proved to be defective in
materials or workmanship under normal use and service. Repaired products
shall be warranted for the remainder of the original Warranty Period.
All transportation costs and in-transit risk of loss or damage related, directly or
indirectly, to products returned to Crow for repair or replacement shall be borne
solely by the Purchaser.
Crow's warranty under this Warranty Certificate does not cover products that is
defective (or shall become defective) due to: (a) alteration of the products (or
any part thereof) by anyone other than Crow; (b) accident, abuse, negligence,
or improper maintenance; (c) failure caused by a product which Crow did not
provide; (d) failure caused by software or hardware which Crow did not provide;
(e) use or storage other than in accordance with Crow's specified operating and
storage instructions.
There are no warranties, expressed or implied, of merchantability or fitness of
the products for a particular purpose or otherwise, which extend beyond the
description on the face hereof.
7101296_F
FIG. 5 - OPTIONAL HOLES
B
LED
Mode
Jumper
PIR
MW
LED LED
A. Wire access holes
B. Use for flat wall mounting or for
mounting with the help of bracket
FIG. 7 - BRACKET MOUNTING AND ASSEMBLY
1
TECHNICAL SPECIFICATIONS
Detection Method
DOUBLE DUAL element PIR & MW
Maximum ripple
2.4Vdc peak to peak at 12Vdc
Power Input
8.2 to 16 Vdc
Current Draw
Start-up: 28mA + 3mA
Standby: 23mA + 3mA
Active :
Temperature
Compensation
YES
Alarm Period
1.8 sec
Alarm Output
N.C 28Vdc 0.1 A with 10 Ohm
series protection resistors
N.O 28Vdc 0.1 A with 10 Ohm
series protection resistors
Tamper Switch
N.C 28Vdc 0.1A with 10 Ohm series
Protection resistor - open when
cover is removed
Warm Up Period
60 sec
This limited Warranty Certificate is the Purchaser's sole and exclusive remedy
against Crow and Crow's sole and exclusive liability toward the Purchaser in
connection with the products, including without limitation - for defects or
malfunctions of the products. This Warranty Certificate replaces all other
warranties and liabilities, whether oral, written, (non-mandatory) statutory,
contractual, in tort or otherwise.
In no case shall Crow be liable to anyone for any consequential or incidental
damages (inclusive of loss of profit, and whether occasioned by negligence of
the Crow or any third party on its behalf) for breach of this or any other
warranty, expressed or implied, or upon any other basis of liability whatsoever.
Crow does not represent that these products can not be compromised or
circumvented; that these products will prevent any person injury or property
loss or damage by burglary, robbery, fire or otherwise; or that these products
will in all cases provide adequate warning or protection.
Purchaser understands that a properly installed and maintained product may in
some cases reduce the risk of burglary, fire, robbery or other events occurring
without providing an alarm, but it is not insurance or a guarantee that such will
not occur or that there will be no personal injury or property loss or damage as
a result.
Consequently, Crow shall have no liability for any personal injury; property
damage or any other loss based on claim that these products failed to give any
warning.
If Crow is held liable, whether directly or indirectly, for any loss or damage with
regards to these products, regardless of cause or origin, Crow's maximum
liability shall not in any case exceed the purchase price of these products,
which shall be the complete and exclusive remedy against Crow.
12
FIG. 6 - WA PIR + MW DETECTION
A
A
B
B
14
16
TECHNICAL SPECIFICATIONS (CONT.)
Operating Temperature
RFI Protection
EMI Protection
Visible Light Protection
20mA + 3mA
MW center frequency
Dimensions
Weight
19
ISRAEL:
USA:
AUSTRALIA:
POLAND:
LATIN AMERICA:
ITALY:
These instructions supersede all previous issues in circulation prior to July 2005.
13
PATTERN
Assembled view
17
-20°C to +50°C(-4°F to +122°F)
30V/m 10 - 1000MHz
50,000V of electrical
interference from lightning or
power through
stable against halogen light
2.4 m (8ft ) or reflected light
X-Band: 9.9 GHz
10.525 GHz
10.687 GHz
154mm x 114mm x 74mm
(6.1" x 4.5" x 2.9")
290gr. (10.23oz)
CROW reserves the rights to change
specifications without prior notice
20
CROW ELECTRONIC ENGINEERING LTD.
Crow Electronic Engineering Ltd.
12 Kineret St. Airport City, 70100
PO. Box 293 Ben Gurion Airport
Tel: 972-3-9726000
Fax: 972-3-9726001
E-mail:
2160 North Central Road,
Fort Lee, N.J. 07024
Tel: 1-800-GET CROW
or
(201) 944 0005
Fax: (201) 944 1199
E-mail:
429 Nepean HWY Brighton East Vic 3187
Tel: 61-3-9596 7222
Fax: 61-3-9596 0888
E-mail:
VIDICON SP. ZO. O.
15 Povazkowska St.
01 – 797 Warsaw Poland
Tel: 48 22 562 3000
Fax: 48 22 562 3030
E-mail:
CROW LATIN AMERICA
ST
5753 NW 151
.Street
MIAMI LAKES,
FL 33014 – USA
Tel: +1-305-823-8700
Fax: +1-305-823-8711
E-mail:
DEATRONIC
VIA Giulianello 4/14
00178 ROMA, ITALY
Tel: +39-0676-12912
Fax: +39-0676-12601
E-mail: