Motorola GM160 Panduan Servis Dasar
3-8
6.
Remove the speaker from the control head housing.
6.5

Disassembly of Control Heads - GM360 and GM380 (with display)

1.
Dismount the control head housing from the back housing as described for control heads
without displays, Figure 3-6 and 3-7.
2.
On the GM360, disconnect the speaker socket and pull out the speaker (with speaker tube)
by stretching the control head housing, Figure 3-9.
NOTE
The speaker and speaker tube are glued together to form one unit. (GM360 only)
3.
Remove the board from the control head housing by stretching the control head housing and
pulling up on the board.
4.
Remove the keypad from the control head housing by lifting up the rubber keypad.
Figure 3-8 Board, Keypad and Speaker Removal
Figure 3-9 Speaker and Speaker Tube Removal
MAINTENANCE
ZWG0130216-O
ZWG0130218-O