1. ALIGMENT
Note: Key the radio while making adjustments or measurments.
1.1 GENERAL
Perform all adjustments at a supply voltage 13.2 ~0.1 volts dc, unless the instruction call for a
different voltage.
Interpret instruction to turn controls clockwise (CW) or counterclockwise (CCW) to mean »as viewed
from the component side of the circuit board«.
Picture A and B show the locations of the components.
When you perform any of the tune-up procedures given in sections 1.2, 1.3, 1.4 and 1.5, the radio
must be completly assembled except for the chassis cover, top cover of the synthesizer compartment,
and the radio sleeve. When you have completed the tune-up, install the synthesizer cover, chassis
cover and sleeve before testing the radio against specifications following the procedures given in
sections 1.4, 1.5, 1.6 and 1.8 .
The following test equipement is recommended for aligning and servicing the MC micro radio:
R2001D
Communication System Analyzer
or
R2200B
GTF180A
GTF244A
Adapter cable for MC micro
PFT4053A
Psophometric filter
FTP3005B
Select 5 test unit (not rquired with R2001D)
R1001B
Power supply
or
S1347D
Power supply (for radios with 10 watts or less power)
R1037
Digital multimeter
or
R1024B
Digital multimeter
1.2 TO ADJUST THE TRANSMITER
(1) Preset the following pots:
* HI PWR
* LO PWR
* VOLT LIMIT
(2) Adjust the radios dc supply voltage to 13.2 ~0.1 VDC (12.6 VDC for MAU1, six-watt model).
(3) Select the channel with highest transmit frequency.
Motorola M110/MC micro aligment (VHF)
Service Monitor
Mobile test set with
R453
R455
R463
Fully CCW
Fully CCW
Fully CW