Toshiba 35UFV-ND Panduan Instalasi - Halaman 5

Jelajahi secara online atau unduh pdf Panduan Instalasi untuk Pendingin Udara Toshiba 35UFV-ND. Toshiba 35UFV-ND 40 halaman.
Juga untuk Toshiba 35UFV-ND: Panduan Pemilik (24 halaman)

Toshiba 35UFV-ND Panduan Instalasi

INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS

INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS
Air fi lter
50 mm or more
3
Batteries
2
Wireless remote control
5
7
Mounting screw
Insulation sheet
When installing the outdoor unit,
leave open in at least two of direction
(A), (B), (C) and (D) shown in the
fi gure on the right.
Remark :
• Detail of accessory and installation
parts can see in the accessory sheet.
CAUTION
Install in rooms that are 13 m
3
or larger.
If a leak of refrigerator gas occurs
inside the room, an oxygen defi ciency
can occur.

Optional Installation Parts

Part
Parts name
code
Refrigerant piping
A
Liquid side : ∅6.35 mm
: ∅9.52 mm
Gas side
Pipe insulating material
B
(polyethylene foam, 8 mm thick)
C
Putty, PVC tapes
1
Installation plate
6
Flat head
4
wood screw
Remote control holder
Vinyl tape
Apply after carrying
out a drainage test.
600 mm or more only
when unobstructed
to the front and both
sides.
• Secure the outdoor unit with fi xing bolts and nuts if the unit is likely to be exposed
Q'ty
to a strong wind.
• Use ∅8 mm or ∅10 mm anchor bolts and nuts.
• If it is necessary to drain the defrost water, attach drain nipple and cap water proof
One
to the bottom plate of the outdoor unit before installing it.
each
1
One
each
X When using a multi-system outdoor unit is used, refer to the installation manual
provided with the model concerned.
3
Do not allow the drain hose to get
slack.
50 mm or more
Make sure to run the drain hose
sloped downward.
The auxiliary piping can be
connected to the left, rear left, rear
right, right, bottom right or bottom
left.
Shield pipe
Right
Rear right
Insulate the refrigerant pipes
separately with insulation, not
together.
Saddle
In case of right or left piping
Extension
drain hose
(Not available,
provided by installer)
Fixing bolt arrangement of outdoor unit
RAS-25, 35S3AVP-ND
108 mm
125 mm
28 mm
Air inlet
Air outlet
90 mm
600 mm
Drain outlet
Cut the piping
hole sloped
EN
slightly.
SV
FI
NO
Left
Rear left
Bottom right
Bottom left
8 mm thick heat resisting
polyethylene foam
Cut dot-line area
* Drain nipple and cap
water proof are packed
in outdoor unit.