CROWN FOOD EC - 10TW Panduan Instalasi dan Pengoperasian - Halaman 6

Jelajahi secara online atau unduh pdf Panduan Instalasi dan Pengoperasian untuk Ketel CROWN FOOD EC - 10TW. CROWN FOOD EC - 10TW 11 halaman. Self-generating steam jacketed counter tilting kettles

INSTALLATION AND OPERATION MANUAL, SELF-GENERATING STEAM JACKETED
COUNTER TILTING KETTLES, EC-6TW, EC-10TW, EC-12TW
1.0 INSTALLATION INSTRUCTIONS (Continued)
DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE
DISCONNECT SWITCH TO INDICATE YOU ARE ON THE CIRCUIT.
9.
A waterproof electrical connection for power supply to console housing must be provided.
10.
Ground appliance to terminal provided inside console housing.
11.
Turn power ON and check for proper operation.
Figure 1
PART NUMBER 10121R3
WARNING
6