Toshiba TLP-S10 Panduan Pemilik - Halaman 21

Jelajahi secara online atau unduh pdf Panduan Pemilik untuk Proyektor Toshiba TLP-S10. Toshiba TLP-S10 22 halaman. 1,200 ansi-lumens 2.1 kg eco mode
Juga untuk Toshiba TLP-S10: Panduan Pemilik (22 halaman), Spesifikasi (2 halaman), Panduan Servis (33 halaman)

Toshiba TLP-S10 Panduan Pemilik
Specifications (Continued)
I CONTROL terminal
G Pin assignment
Pin No.
7
8
6
5
3
4
2
1
Mini DIN 8 pin connector
G Interface format
1 Communication method
RS-232C, 9600bps, No Parity, Data Length: 8 bits;
Stop Bit Length:
2 Communication format
STX (02h) Command (3Byte) ETX (03h)
Only 1 command valid per communication.
3 Data format
For input commands, only ASCII-compliant all-uppercase
alphanumeric characters supported.
4 Replies
Acknowledge
No acknowledge
If commands are to be sent consecutively, wait for the response from the projector
before sending the next command.
G Main Commands
Item
Command
Power on
PON
Power off
POF
Icon display on
MO0
Icon display off
MO1
Auto setting (RGB input)
PAT
Status display on
DON
Status display off
DOF
Note
• Contact your dealer for control cable and other commands.
I Separately Sold Product
Replacement Lamp
Model TLPLV3
Note
• Design, specifications, etc. subject to change without notice for improvements, etc.
Signal Name
Description
1
RXD
Receiving data
2
CTS
Consent to send
3
DSR
Data set ready
4
GND
Signal ground
5
RTS
Request to send
6
N.C
No connection
7
TXD
Sending data
8
N.C
No connection
1 bit
ACK (06h) CR (0Dh) Data
... Normally ended
ACK (06h) ESC (1Bh)
... Aborted
NAK (15h)
Item
Computer input select
Y/P
/P
input select
B
R
Video input select
S-video input select
40
Command
IN1
IN2
IN3
IN4