WARNING
This heater is not equipped with a device to control the
room temperature. Do not use this heater in small rooms when they
are occupied by persons not capacble of leaving the room on their
own, unless constant supervision is provided.
This appliance is not intended for use by persons (inlcuding children)
with reduced physical, sensory or metal capabilities, or lack of
experince and knowledge, unless they have been given supervision
or instruction concerning use of the apppliance by a person
responsible for their safety.
Children should be supervised to ensure that they do not play with
the appliance.
Maintenance
WARNING: ALWAYS DISCONNECT HEATER FROM THE POWER
SUPPLY BEFORE ATTEMPTING ANY MAINTENANCE.
Thermal Safety cut-out(s)
The power supply to the heating elements will be interrupted if one or a
combination of the following abnormal events occur:
1.
Air inlet/outlet panel is obstructed.
2.
I n t e r n a l v e n t i l a t i o n i s i m p a i r e d d u e t o b u i l d u p o f d u s t
and fl uff.
3.
Blower unit stalls.
Note : If the cut-out operates, the fan may continue to run impairing the
performance of the heater. The heater must be turned off immediately and
the cut-out(s) reset following the 'Procedure for resetting cut-out(s)'.
DIMPLEX
MILLBROOK HOUSE
GRANGE DRIVE
HEDGE END
SOUTHAMPTON
SO30 2DF
[c] GDC Group Ltd,
All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of Dimplex.
A division of GDC Group Ltd,
Procedure for resetting cut-out(s)
Establish cause and eliminate.
You need to reset thermal cut-out(s), located behind the Air Inlet/Outlet panel
(for detail view see Fig. 11).
To reset the thermal safety cut-out, press the black reset button (see 'g' in
Fig. 11) on the side of the cut-out (see 'f' in Fig. 11) as described in steps
2 - 4 :-
Steps to reset cut-out(s)
1.
Disconnect power supply.
2.
Pass small fl at head screwdriver through Air Inlet/Outlet panel 'B' to
button side of cut-out (see 'g' in Fig. 11) avoiding contact with element
(see 'e' in Fig. 11).
3.
Press reset button in direction shown in Fig. 11 to reset cut-out.
(Cut-out clicks when reset)
4.
Remove screwdriver carefully.
5.
Turn on supply.
If the cut-out continues to operate intermittently, the heater should be switched
off and a service agent contacted.
e
f
g
Cleaning of Heater / Switch Panel
External and grille appearance can be maintained by occasionally vacuuming
or wiping with a light duster. External appearance of the Switch Panel can be
maintained by wiping occasionally with a light duster or for stain removal, a
weak soap solution can be applied with a cloth and the surface wiped dry.
Note: Care must be taken to avoid any moisture ingress into the switch
panel.
After Sales Service
Your product is guaranteed for one year from the date of purchase.
Within this period, we undertake to repair or exchange this product free of
charge provided it has been installed and operated in accordance with these
instructions.
Your rights under this guarantee are additional to your statutory rights, which
in turn are not affected by this guarantee.
Should you require after sales information or assistance with this product
please go to www.dimplex.co.uk where you will fi nd our self help guide by
clicking on "After Sales" or ring our helpdesk on 0845 600 5111 (UK) or 01
842 4833 (R.O.I.) .
Spare parts are also available on the website www.dimplex.co.uk
Please retain your receipt as proof of purchase.
TEL: 0845 600 5111
FAX: 01489 773050
WEBSITE: www.dimplex.co.uk
Republic of Ireland
e
B
f
g
Tel.
01 8424833
Fig. 11