Dimplex AS12 Series Petunjuk Instalasi - Halaman 2
Jelajahi secara online atau unduh pdf Petunjuk Instalasi untuk Pemanas Dimplex AS12 Series. Dimplex AS12 Series 3 halaman. Architectural heaters
Juga untuk Dimplex AS12 Series: Petunjuk Instalasi (3 halaman)
wall to keep the heater level.
!
nOTe: Should the wall surface be uneven, secure
the heater back panel to the high spots. This will avoid a
distorted appearance.
5.
proceed to the wiring instructions.
Floor installation
1.
Unpack the heater and pedestal(s) from the carton( the
pedestals are packed at the end of the carton) .
2.
Remove the front panel and terminal box covers.
!
nOTe: The front panel screws are recessed in the
bottom louvers at each end of the heater.
3.
Remove the desired knockouts from the terminal box
area.
!
nOTe: it is only necessary to remove the knockout(s)
that will feed the power supply wiring, keeping in mind
the heater mounting location and supply wire location on
the wall.
4.
Temporarily secure a pedestal to each end of the heater
bottom.
!
nOTe: Units longer than 4 feet will be provided with 3
or more pedestals. The extra pedestals should be used
Wiring Diagrams
HEaTER No CoNTRoLs - 1 pH paRaLLEL
ELEmENT
L1
LimiT CoNTRoL
L2
RETuRN WiREs
HEaTER No CoNTRoLs - 3 pH DELTa
ELEmENT
L1
LimiT CoNTRoL
L2
RETuRN WiREs
L3
HEaTER 2 poLE sTaT - 1 pH paRaLLEL
ELEmENT
LimiT CoNTRoL
sTaT
L1
L2
RETuRN WiREs
HEaTER c/w 2 or 3 poLE sTaT - 3 pH DELTa
LimiT CoNTRoL
sTaT
L1
L2
L3
RETuRN WiREs
7106223000
2
HEaTER LVD RELaY - 1 pH paRaLLEL
LimiT CoNTRoL
L1
L2
7106222200
HEaTER LVC RELaY - 1 pH paRaLLEL
L2
LimiT CoNTRoL
L1
L3
HEaTER 3 poLE CoNTaCToR - 3 pH DELTa
7106222500
LimiT CoNTRoL
L1
L2
7106222700
HEaTER 3 poLE CoNTaCToR/TX - 3 pH DELTa
ELEmENT
LimiT CoNTRoL
L1
L2 L3
to support the middle of the heater.
5.
place the heater in the desired location and mark the
position of the pedestal base on the floor.
6.
Remove the pedestal base(s) from the heater and
secure to the floor within the marked areas with suitable
fasteners. (provided by the customer)
7.
place the heater on the pedestal base and tighten all
fasteners.
8.
proceed to wiring instructions.
Wiring instructions
Recommended minimum supply wire sizes are listed in the
table below:
mAximum WATTS per circuiT uSinG 75 °c Wire
Rough in
Wire size
14
12
10
1.
Run branch circuit wiring of proper voltage and wire size
to the location of the terminal box of the heater. (See
ELEmENT
RELaY
a
RETuRN WiREs
L1
7106223700
ELEmENT
RELaY
a
B
RETuRN WiREs
L2
7106223200
ELEmENT
24V
RETuRN WiREs
CoNTaCToR
7106224000
ELEmENT
24V
RETuRN WiREs
CoNTaCToR
7106223500
(cOpper Wire)
120V 208V 240V 277V 347V
1440
2496
2880
3324
1920
3328
3840
4432
2880
4992
5760
6648
Chart)
!
nOTe: supply wire entry is
commonly made into one heater.
Through wiring (factory furnished)
T2
can be used for connection to
T1
adjacent heaters.
C
2.
Wire all heaters and controls in
accordance with the appropriate
L2
wiring diagram.
!
nOTe: sample wiring diagrams
beside.
3.
Wrap the supply ground wire
T2
around the green painted ground
T1
screw & tighten.
!
nOTe: When heaters are mounted
C
end to end, remove the finished
L1
end plate, install a chase nipple
and locknut in the terminal box to
T2
ensure grounding continuity and to
T1
protect the wiring.
Where headers are spaced apart,
remove the finishing end plate, and use
rigid conduit (provided by customer) for
L1
L2
through wiring and ground continuity.
L3
Do not exceed the allowable number
of conductors allowed by the National
Electric Code.
T2
4.
Do a final and complete check of all
T1
wiring then replace the terminal box
covers being careful not to pinch
any wires.
L1
5.
The front panel may now be
L2
installed.
L3
480V
600V
4164
5760
7200
5552
7680
9600
8328
11520
14400
www.dimplex.com