Cruise N Comfort MES 12 L Panduan Petunjuk Pemasangan & Pengoperasian - Halaman 4

Jelajahi secara online atau unduh pdf Panduan Petunjuk Pemasangan & Pengoperasian untuk Pendingin Udara Cruise N Comfort MES 12 L. Cruise N Comfort MES 12 L 7 halaman. 12volt marine air conditioners

Qty. 1- 1/2" Inline water strainer
Qty. 1-Thru-hull 1/2" water dump
Qty. 1-Thru-hull 1/2" water pickup GROCO 34 STH500W 1/2"
Qty. 1-70 amp waterproof and explosion proof resettable breaker.
* 4 Gauge marine grade power and ground wire. Solder, crimp and
heat shrink 3/8" marine grade terminals
* Measure from the battery to
the mounting location of the unit to determine length. Avoid
splicing if possible.
* 1/2" marine grade vinyl reinforced hose. Measure from the unit
to the water fittings below and above the water line.
Qty.1 -12 volt self priming pump, continuous duty, run dry capable
(3 gallon per minute minimum)

Maintenance

Winter:
1.
In climates that reach 32 degrees F you must remove all water so that it
does not freeze. Shoot pressured air into the outlet hole for at least 30 seconds to
remove any water in the system.
Bi-Monthly:
2.
a.
Check, clean or replace air intake filter on front of evaporator.
b. Check, clean or replace water pump filter/strainer (not included)
c. check system and hoses for water leaks, especially 2 hoses inside unit fix any as
required.
d. check evaporator condenser drain for blockages.

Troubleshooting

Page
4
of
7