Pioneer GM-4200 Panduan Servis - Halaman 15
Jelajahi secara online atau unduh pdf Panduan Servis untuk Penguat Pioneer GM-4200. Pioneer GM-4200 35 halaman. Bridgeable power amplifier
Juga untuk Pioneer GM-4200: Panduan Servis (36 halaman)
7. CIRCUIT DESCRIPTION
• Isolator circuit
The differential amplification circuit, which is usually
combined with the operational amplifier and the resist¬
ance network, is arranged to the dedicated 1C.
The ripple removal ratio is further improved than the
conventional differentia! amplification circuit.
• Non-switching circuit type ID
By adding Q429 to Q432, distortion removal capacity is
improved.
• PWM POWER SUPPLY {Voltage detection circuit for
both positive and negative voltage.)
The PWM power supply is a circuit that maintains stable
secondary voltage in a DC-DC converter, regardless of the
voltage fluctuation and load fluctuation of the primary
voltage.
Former PWM power supply detected and controlled only
positive voltage of DC-DC converter. New PWM power
supply increases output in the lower range through detect¬
ing and controlling both positive and nagative voltages
and it creates a higher fidelity sound.
{Manufacture the current mirror using Q114andQ115, and
input —VH into the pin 16 of IC101 through Q116. 4-VH is
input through Q117. R131 toR134are the voltage dividers.)
• Troidal transformer and others
To improve efficiency and to delete the leakage flux, the.
"doughnut" type transformar is adopted. And corre¬
sponding to current increment, two fuse, choke coil paral¬
lel combinations. (L101, L102)
• DC servo
To reduce the DC component appeared in the output, DC is
fed back by means of IC201 and IC202. This circuit
performs the low-pass feed back of less than 200Hz simul¬
taneously.
• In this unit, the mode selecting circuit was simplified in the following manners.
©Always inverse
©The output side is indicated
phase
as (-).(For the speakers,left
and right channels are of the
same phase.)
Fig. 4
Figure shows the case of UC, EW carries out ® and (D on the
right channel.
For the above two reasons, a signal selector switch was
eliminated.
When you make a test, take care not to short-circuit
(OUTPUT) and (GND). Especially when you measure two
channels at the same time, a great care must be taken
because short-circuit is susceptible to take place at the
measuring instrument.
15