Aeotec AEOEZWA009 Manual - Halaman 4

Jelajahi secara online atau unduh pdf Manual untuk Aksesori Aeotec AEOEZWA009. Aeotec AEOEZWA009 7 halaman.

Aeotec AEOEZWA009 Manual
3
4
5
6

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt
the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ...
255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to
200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic
applies: Values greater than 32768 may needed to be given as negative values too.
Parameter 1: Minimum Temperature change to report
This value defines the minimum change of temperature to cause an unsolicited report of humidity to the central
controller using Lifeline. If the value is set to 0, there will be no reports sent to the controller, when the
temperature changes. However, periodic reports, managed by configuration parameter 4, may still be active.
Size: 1 Byte, Default Value: 20
Setting
0
1 - 100
Parameter 2: Minimum humidity change to report
This value defines the minimum change of humidity to cause an unsolicited report of humidity to the central
controller using Lifeline. If the value is set to 0, there will be no reports sent to the controller, when the humidity
changes. However, periodic reports, managed by configuration parameter 4, may still be active.
Size: 1 Byte, Default Value: 5
Setting
0
1 - 20
Parameter 4: Periodic Reports
This parameter defines the time interval to send an unsolicited report. If the value is set to 0, there will be no
periodic reports sent to the controller. However, reports on temperature/humidity changes, managed by
configuration parameters 1 and 2, may still be active.
Size: 2 Byte, Default Value: 43200
Setting
0
900 - 65535
Parameter 5: Temperature Upper Watermark value
This parameter defines a temperature. If the measured temperature surpasses this watermark a BASIC
command is sent into Association Group 2
Size: 2 Byte, Default Value: 0
5
Low Temperature Notification
5
High Humidity Notification
5
Low Humidity Notification
5
Air Temperature (A multilevel sensor report is sent to the
nodes in this group)
Description
disabled
1/10 degree
Description
disabled
%
Description
disabled
Seconds