Ariston AURES EASY 3.5 Manual Petunjuk Perakitan dan Pengoperasian - Halaman 22
Jelajahi secara online atau unduh pdf Manual Petunjuk Perakitan dan Pengoperasian untuk Pemanas Air Ariston AURES EASY 3.5. Ariston AURES EASY 3.5 28 halaman. Instantaneous electric water heater
ID
Troubleshooting
PROBLEM
Cold Water
no temperature increase
Water temp increased,
but not warm enough
Flow rate
too small
House light flickering
when heating
HEATING
LAMP
CHECKING ACTIONS
1. Make sure power supplier is available, by checking house pow-
er supply voltage;
2. Make sure the "ELCB" button is not accidentally pressed.
OFF
3. Make sure the water heater is turned ON, by checking the knob
position.
4. Make sure the water pipe connection is correct (inlet on right,
outlet on left).
1. Make sure temperature setting is not too small, by increasing
the setting power level.
2. Make sure the water flow rate is not too high (over 6L/min), by
reducing the flow rate through the water regulation valve.
3. Measuring the actual voltage DURING heating to make sure
ON
the voltage drop is not too big.
Increasing the diameter or reducing the length of the power
supply cable may resolve the problem.
4. Make sure the supplying voltage is not too small by checking
the house power supply voltage WITHOUT heating.
1. Make sure the water pressure is high enough (the water tank
should be at least 3 meters higher than the water heater).
2. Make sure there is nothing blocking the water flow by cleaning
the built-in water filter inside the water valve.
--
3. Make sure there is nothing blocking the nozzles of the shower
head.
4. Make sure there is nothing blocking the flow of water from the
main water supply point to the inlet pipe.
Measuring the actual voltage WHEN heating to make sure volt-
age drop not too big. (Voltage drop should be less than 10%).
ON
By increase section, or reduce length of the power supply cable
could solve the flickering problem.
22 22