ABB 30-050-07 Manual Petunjuk Asli - Halaman 7

Jelajahi secara online atau unduh pdf Manual Petunjuk Asli untuk Unit Kontrol ABB 30-050-07. ABB 30-050-07 12 halaman. Emergency stop with indication

ABB 30-050-07 Manual Petunjuk Asli

4 Installation and maintenance

Installation precautions

First mount Smile Tina to the surface with two M5 bolts, and then attach the M12 connection(s).
Warning! All the safety functions must be tested before starting up the system.

Maintenance

Warning! The safety functions and the mechanics shall be tested regularly, at least once every year
to confirm that all the safety functions are working properly (EN 62061:2005).
Warning! In case of breakdown or damage to the product, contact Jokab Safety. Do not try to repair
the product since it may accidentally cause permanent damage, impairing the safety of the device
which in turn could lead to serious injury to personnel.

Testing of the safety functions

Make sure the safety unit is working properly by following these steps:
Interrupt the dynamic safety circuit before this unit. The LED should flash between green and
red.
Interrupt protection (i.e. push the E-stop button). The LED should light red.
The LED should light green when protection is OK and the safety circuit is not previously
broken.

Troubleshooting

LED indicator note
Lights red
No lights
Lights green (but no dynamic
output detected)
Weak lights or red and green
lights at the same time
NB: Tina 1A can be used instead of this unit to check if the safety circuit is OK (only for test).
Warning! Replace a defected unit with a new one and never bypass the safety circuit using Tina 1A
or any other solution.
Smile_Tina_Manual_(English)_v1A
2010-10-19
Expected causes of faults
E-stop button is down
24 VDC input to pin-2 (no
dynamic signal)
Loss of power supply
Defected dynamic signal
input to unit (asymmetric
pulses)
The unit is defect
Checking and measures to take
Reset the button by turning it
clockwise and pulling it upward.
Check if there is 24 VDC to input (pin-
2). If Yes, check cable or unit before
and fix it.
Check 24 VDC / 0 VDC power supply
Check the dynamic input or the unit
before
The unit needs to be replaced.
Contact Jokab Safety.
www.jokabsafety.com
7