Setting
10 - 255
Parameter 64: Set the default unit of the automatic temperature report in parameter 101-103.
Set the default unit of the automatic temperature report in parameter 101-103.
Size: 1 Byte, Default Value: 1
Setting
0
1
Parameter 84: Get the state of tilt sensor
Get the state of tilt sensor.Note: this is a Get-only parameter.
Size: 1 Byte, Default Value: 0
Setting
0
1
Parameter 86: Enable/ disable the buzzer.
Enable/ disable the buzzer.
Size: 1 Byte, Default Value: 1
Setting
0
1
Parameter 87: To set which sensor is triggered the buzzer will alarm.
To set which sensor is triggered the buzzer will alarm.
Size: 4 Byte, Default Value: 55
Setting
1
2
4
16
32
Parameter 88: To set which value of the Basic Set will be sent to the associated nodes in association Group 3 when
the Sensor probe 1 is triggered.
To set which value of the Basic Set will be sent to the associated nodes in association Group 3 when the Sensor probe 1 is triggered.
Size: 1 Byte, Default Value: 0
Setting
0
1
2
Parameter 89: To set which value of the Basic Set will be sent to the associated nodes in association Group 4 when
the Sensor probe 2 is triggered.
To set which value of the Basic Set will be sent to the associated nodes in association Group 4 when the Sensor probe 2 is triggered.
Size: 1 Byte, Default Value: 0
Setting
0
1
2
Parameter 94: To set which power source level is reported via the Battery CC.
To set which power source level is reported via the Battery CC.
Description
Available rang is 1.0°C to 25.5°C
Description
The unit is Celsius.
The unit is Fahrenheit.
Description
The Water Sensor main unit is in horizontal direction.
The Water Sensor main unit is in vertical direction.
Description
Disable
Enable
Description
If the Water leak is triggered, the buzzer will alarm.
If the vibration is triggered, the buzzer will alarm.
If the tilt sensor is triggered, the buzzer will alarm.
If the under heat is triggered, the buzzer will alarm
If the overheat is triggered, the buzzer will alarm.
Description
Send nothing
Presence of water, send Basic Set 255 (0xFF), absence of water, send Basic Set 0 (0x00).
Presence of water, send Basic Set 0 (0x00), absence of water, send Basic Set 255 (0xFF).
Description
Send nothing.
Presence of water, send Basic Set 255 (0xFF), absence of water, send Basic Set = 0 (0x00).
Presence of water, send Basic Set 0 (0x00), absence of water, send Basic Set 255 (0xFF).