Ariston EP 10 UR 3KW Manual - Halaman 14

Jelajahi secara online atau unduh pdf Manual untuk Pemanas Air Ariston EP 10 UR 3KW. Ariston EP 10 UR 3KW 17 halaman. Unvented water heater

Ariston EP 10 UR 3KW Manual
12
3)Dripping while unit heating.
Cause: Not enough pipe work for expansion; or stop-cock, non-return
valve or pressure reducing valve has been fitted within the
distance required for expansion (see page 5, Fig.3). If an
expansion vessel has been fitted, the charge may have failed.
4)No hot water.
Cause: Thermal cut-out has operated.
The heating element has burnt-out.
The thermostat is faulty.
5)Milky water.
Cause: This is a result of heavily limed and oxygenated water being
heated. This is harmless and the cause is the water and not
the heater.
6)No water at all.
Cause: Valve incorrectly fitted.
Debris in the mains.
Mains water supply turned off.