If you're using a Z-Stick:
If you're using a Minimote:
Remove
Action Button
1. If your Z-Stick is plugged into a gateway or a
computer, unplug it.
1. Take your Minimote to your Recessed Door
2. Take your Z-Stick to your Recessed Door
Sensor.
Sensor. Hold the Action Button on your Z-Stick
2. Press the Remove button on your Minimote.
for 3 seconds.
3. Press the Z-Wave Button on your sensor with
3. Press the Z-Wave Button on your sensor
a small pin or toothpick.
with a small pin or toothpick.
4. If your Recessed Door Sensor has been
4. If your sensor has been successfully removed
successfully removed from your network,
from your network, its LED light will blink for
its LED light will blink for 3 seconds when
3 seconds when you press the Z-Wave Button.
you press the Z-Wave Button. If the removal
If the removal was unsuccessful, its LED light
was unsuccessful, its LED light will remain
will remain illuminated for 3 seconds.
illuminated for 3 seconds.
5. Press the Action Button on your Z-Stick to
5. Press any button on your Minimote to take it
take it out of removal mode.
out of removal mode.
Reset your sensor.
the manifestation of a problem. Aeon Labs' sole
obligation under the foregoing warranty is, at
At some stage, you may wish to reset all of
Aeon Labs' option, to repair, replace or correct
your Recessed Door Sensor's settings to their
any such defect that was present at the time
factory defaults. To do this, press and hold the
of delivery, or to remove the Products and to
Action Button for 20 seconds and then release
refund the purchase price to Customer.
it. Your sensor will now be reset to its original
The "Warranty Period" begins on the date the
settings.
Products is delivered and continues for 12
months.
Technical specifications.
Any repairs under this warranty must be
conducted by an authorized Aeon Labs service
Operating distance: Up to 300feet/100metres
representative and under Aeon Labs' RMA
outdoors.
policy. Any repairs conducted by unauthorized
Battery: Lithium cell CR2, 3 volt battery, 800mAh.
persons shall void this warranty.
Operating temperature: -10
C
to 50 .
C
Relative humidity: 8% to 80%.
Excluded from the warranty are problems
due to accidents, acts of God, civil or military
6
Warranty.
authority, civil disturbance, war, strikes, fires,
other catastrophes, misuse, misapplication,
Aeon Labs warrants to the original purchaser
storage damage, negligence, electrical power
of Products that for the Warranty Period (as
problems, or modification to the Products or its
defined below), the Products will be free from
components.
material defects in materials and workmanship.
Aeon Labs does not authorize any person
The foregoing warranty is subject to the proper
or party to assume or create for it any other
installation, operation and maintenance of
obligation or liability in connection with the
the Products in accordance with installation
Products except as set forth herein.
instructions and the operating manual supplied
Aeon Labs will pass on to Customer all
to Customer. Warranty claims must be made
manufacturers' Material warranties to the extent
by Customer in writing within thirty (30) days of
that they are transferable, but will not
trademark, mask work, copyright, trade secret
independently warrant any Material.
or any actual or alleged violation of any other
intellectual property rights arising from or in
C u s t o m e r m u s t p r e p a y s h i p p i n g a n d
connection with the products, except to the
transportation charges for returned Products,
extent that such infringement exists as a result
and insure the shipment or accept the risk of
of Aeon Labs' manufacturing processes.
loss or damage during such shipment and
transportation. Aeon Labs will ship the repaired
IN NO EVENT SHALL AEON LABS BE LIABLE FOR
ANY INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL OR
or replacement products to Customer freight
CONSEQUENTIAL DAMAGES, OR DAMAGES FOR
prepaid.
LOSS OF PROFITS, REVENUE, OR USE INCURRED
Customer shall indemnify, defend, and
BY CUSTOMER OR ANY THIRD PARTY, WHETHER
IN AN ACTION IN CONTRACT, OR TORT, OR
hold Aeon Labs and Aeon Labs' affiliates,
OTHERWISE EVEN IF ADVISED OF THE POSSIBILITY
shareholders, directors, officers, employees,
OF SUCH DAMAGES. AEON LABS' LIABILITY AND
contractors, agents and other representatives
CUSTOMER'S EXCLUSIVE REMEDY FOR ANY
harmless from all demands, claims, actions,
CAUSE OF ACTION ARISING IN CONNECTION WITH
causes of action, proceedings, suits,
THIS AGREEMENT OR THE SALE OR USE OF THE
PRODUCTS, WHETHER BASED ON NEGLIGENCE,
assessments, losses, damages, liabilities,
STRICT LIABILITY, BREACH OF WARRANTY,
settlements, judgments, fines, penalties,
B R E A C H O F A G R E E M E N T, O R E Q U I TA B L E
interest, costs and expenses (including fees
PRINCIPLES, IS EXPRESSLY LIMITED TO, AT AEON
and disbursements of counsel) of every kind (i)
LABS' OPTION, REPLACEMENT OF, OR REPAYMENT
based upon personal injury or death or injury
OF THE PURCHASE PRICE FOR THAT PORTION OF
to property to the extent any of the foregoing
PRODUCTS WITH RESPECT TO WHICH DAMAGES
ARE CLAIMED. ALL CLAIMS OF ANY KIND ARISING
is proximately caused either by a defective
IN CONNECTION WITH THIS AGREEMENT OR THE
product (including strict liability in tort) or
SALE OR USE OF PRODUCTS SHALL BE DEEMED
by the negligent or willful acts or omissions
WAIVED UNLESS MADE IN WRITING WITHIN THIRTY
of Customer or its officers, employees,
(30) DAYS FROM AEON LABS'S DELIVERY, OR THE
subcontractors or agents, and/or (ii) arising
DATE FIXED FOR DELIVERY IN THE EVENT OF
NONDELIVERY.
from or relating to any actual or alleged
infringement or misappropriation of any patent,
THE INDEMNITY AND WARRANTY IN ABOVE
interference in a residential installation.
ARE EXCLUSIVE AND IN LIEU OF ALL OTHER
This equipment generates, uses and
INDEMNITIES OR WARRANTIES, WHETHER
can radiate radio frequency energy and,
EXPRESS OR IMPLIED, INCLUDING THE IMPLIED
if not installed and used in accordance
WARRANTIES OF MERCHANTABILITY AND FITNESS
with the instructions, may cause harmful
FOR A PARTICULAR PURPOSE.
interference to radio communications.
FCC NOTICE (for USA)
However, there is no guarantee that
THE MANUFACTURER IS NOT RESPONSIBLE
interference will not occur in a particular
FOR ANY RADIO OR TV INTERFERENCE CAUSED
installation. If this equipment does cause
BY UNAUTHORIZED MODIFICATIONS TO THIS
harmful interference to radio or television
EQUIPMENT.SUCH MODIFICATIONS COULD
reception, which can be determined by
VOID THE USER'S AUTHORITY TO OPERATE THE
turning the equipment off and on, the
EQUIPMENT.
user is encouraged to try to correct the
STORE INDOORS WHEN NOT IN USE. SUITABLE
FOR DRY LOCATIONS. DO NOT IMMERSE IN
interference by one or more of the following
WAT E R . N O T F O R U S E W H E R E D I R E C T LY
measures:
EXPOSED TO WATER.
Reorient or relocate the receiving antenna.
This device complies with Part 15 of the FCC
Increase the separation between the
Rules. Operation is subject to the following two
equipment and receiver.
conditions:
Connect the equipment into an outlet on
1
This device may not cause harmful
a circuit different from that to which the
interference, and
receiver is connected.
2
This device must accept any interference
Consul the dealer or an experienced
received, including interference that may
radio/TV technician for help.
cause undesired operation. This equipment
has been tested and found to comply
with the limits for a Class B digital device,
Warning
pursuant to part 15 of the FCC Rules.
Do not dispose of electrical appliances as
These limits are designed to provide
unsorted municipal waste, use separate
reasonable protection against harmful
collection facilities.
Contact your local government for information
regarding the collection systems available.
Certifications (regional):
Z-Wave and Z-Wave Plus are
registered trademarks of Sigma
Designs and its subsidiaries in the
United States and other countries
Version:501008900001-AA
www.aeotec.com