Ariston ST 100 ProTech Petunjuk Pemasangan, Servis, dan Penggunaan - Halaman 3

Jelajahi secara online atau unduh pdf Petunjuk Pemasangan, Servis, dan Penggunaan untuk Pemanas Air Ariston ST 100 ProTech. Ariston ST 100 ProTech 36 halaman. Unvented hot water storage cylinders
Juga untuk Ariston ST 100 ProTech: Petunjuk Instalasi dan Penggunaan Manual (24 halaman), Panduan Pengguna (16 halaman), Petunjuk Pemasangan, Servis & Pengoperasian (34 halaman)

Ariston ST 100 ProTech Petunjuk Pemasangan, Servis, dan Penggunaan
2.
GENERAL
INFORMATION
2.1
G
uArAntee
2.2
H
A
ow tHe
ppliAnce
w
orks
This manual is an integral and essential part of the product. It should be kept
with the appliance so that it can be consulted by the user and/or authorised
personnel.
Please read carefully the instructions and notices about the appliance
contained in this manual, as they provide important information regarding the
safe installation, use and maintenance of the cylinder.
Failure to do so may invalidate the guarantee.
When installing and servicing the cylinder, Ariston Thermo UK Ltd
recommend the use of protective clothing i.e. gloves.
The Ariston range of unvented cylinders come with varying guarantees
depending on the model of cylinder. The guarantee periods offered with
each model of cylinder are as follows:
ST Range
Classico HE Range
Aquabravo Range
Note: The guarantee is subject to the cylinder being installed and serviced
annually by a competent person as per the maintenance instructions in
Section 5.6 of this manual. For units with the ProTech anti-corrosion device
it must be ensured that this is connected and operating correctly (green LED
only).
The immersion heater(s) are controlled through a thermostat which senses
the water temperature. The operating temperature can be pre-set by
adjusting the spindle in the head of the thermostat. In addition to the
thermostat there is a thermal cut-out incorporated if the thermostat fails and
the water temperature rises too high. Once the cut-out operates it can only
be re-set manually after the fault has been rectified.
Indirect models have dual thermal controls. In addition to the above there is a
separate cylinder thermostat and thermal cut-out for controlling each indirect
circuit. Again the thermal cut-out operates if the cylinder thermostat fails, by
disconnecting the live feed (call for hot water) from the programmer.
ITI/ITD/ITSI models have a stainless steel tank and therefore need no
protection against corrosion.
STD/STI models have an enamelled steel tank and therefore are supplied
with magnesium anodes to prevent corrosion of the cylinder tank. It is
imperative that the top anode is checked during the annual service and if
found to be corroded both anodes should be replaced. Failure to do so will
invalidate the warranty of the tank.
The Wall-hung (ST) units utilise the ProTech anti-corrosion system
(electronic anode). This prevents an electrolytic reaction between the tank
and dissimilar metals. The ProTech system shows if it is operating correctly
(green LED) or incorrectly (red LED). In the event that the red LED lights
(even with the green light still showing), it is imperative that a service agent
is contacted immediately as continued use with the ProTech system in this
state could invalidate the warranty on the tank.
Note: Do not use a water softner on products with the ProTech anti-corrosion
system.
-
10 Years tank
-
2 Years electrical components
-
5 Years tank
-
2 Years electrical components
-
25 Years tank
-
2 Years electrical components
3