ABB ACH550 series Panduan Pengguna - Halaman 13
Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Unit Kontrol ABB ACH550 series. ABB ACH550 series 14 halaman. Pumpsave 4.1, energy savings calculator for pump drives
Juga untuk ABB ACH550 series: Panduan Pemasangan, Pengoperasian, dan Pemeliharaan (18 halaman), Panduan Memulai Cepat (6 halaman)
Q
H
n
P
In the calculation sheets, calculations are at single points for Q = 20% to 100%
of nominal pump flow Qn. Q is the actual flow. H is the total dynamic head at
flow Q. The efficiency figures are multiplied with k-factors witch take into
account operating conditions with some accuracy. These correcting factors are
defined based on experience.
Efficiency
100 %
DRIVE
95 %
80 %
Graph 2. Typical efficiencies.
This gives the following formulas for power calculations:
Frequency converter control
Pvsdi
p
kmi
Qi
Qn
kvsdi
table
Throttling control, assuming constant motor efficiency
Qi
Pthi
p
kpi
Qi
2
4 .
ON/OFF control, assuming constant motor and pump efficiency
P
ON
OFF
_
avg
. 0
981
n
p
MOTOR
PUMP
Qi
Hsi
. 9
81
m
kmi
kvsdi
*
vsd
0
2 .
0
2 .
Hst
Hn
Hpi
. 9
81
, where
kpi
m
. 1
44
Qi
Qn
Qn
Qi
Hn
. 9
81
p
m
vsd
m
p
Flow
, where
13