Ariston TI PRO 15 OR 350 ID Panduan Pengguna - Halaman 8

Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Pemanas Air Ariston TI PRO 15 OR 350 ID. Ariston TI PRO 15 OR 350 ID 13 halaman. Electric water heater

Ariston TI PRO 15 OR 350 ID Panduan Pengguna
GB

Installation instructions

The appliance must be installed as close as possible to the point where it is to be
used to avoid heat dispersion along the piping.
To facilitate maintenance operations, leave a space of 50 cm for access to the
electrical parts. The wall attachment hooks must support a weight three times that
of the water heater filled with water. The use of not less than 8mm diameter hooks
is suggested.
The supported screws only use for concrete wall or solid wall, user could use
other kinds of screws according to the structure of the wall.
For capacity 10-30 L
The range of the water-heaters includes models prepared for being fitted over or
under the point of use (wash-basin, sink). The models to be fitted under the point of
use called "under sink").
Fasten the supporting bracket provided to the wall using screws and raw plugs of
suitable dimensions for the type of wall.
Hook the water heater to the bracket and pull it downwards to make sure it has been
fastened correctly.
Connect the water heater's inlet and outlet with pipes or fittings that are resistant to
Water
the working pressure as well as to the temperature of the hot water that can usually
connection
reach and exceed 80˚ C. We therefore advise against the use of materiales
that do not resist such high temperatures.
Screw a "T" piece union to the water inlet pipe with the blue collar. On one side of the
"T" piece union, screw a tap for emptying the appliance that can only be opened
with the use of a tool (B fig. 1). On the other side of the "T" piece union screw the
safety valve supplied (A fig. 1). This should be connected to the cold water network
via a flexible pipe. In the case that the emptying tap should be opened, also attach
a waste pipe to exit (C fig. 1).
When fixing the safety valve, do not force in excessively and do not tamper with the
same.
The safety valve is set at about the value shown in the technical label (*). Slight
dripping is normal during heating; for this very reason, we recommend you
connect this drain, leaving it always open, to a drain pipe installed inclined
continuosly downwards and place without condensation. If the mains pressure is
very close to the valve rating, install a pressure reducing unit as far as possible from
the appliance.
If installing mixer units (tap fittings or shower), clear the piping from all impurities
which might damage the same.
"Open outlet"
For this type of installation it is needed to utilise suitable watertaps and carry out
connection
the connection as shown in the scheme fig. 1A. With this solution the water-heater
can operate at any network pressure. The safety valve is not to be fitted.
For capacity 10-30 L
Electrical
The feeding cable (type H 05 VV - F 3x 1 diameter 8,5 mm) is to be inserted in the
connection
proper hole F fig. 3 situated in the back of the apparatus and slide it until it reaches
the housing slot V fig. 4 near the thermostat. To disconnect the unit from the network
use a bipolar switch conform to CEI-EN standards (contact opening at least 3 mm,
better if equipped with fuses). The feeding cable is then connected to the clamps (M
fig. 4).
The appliance must be earthed and the earth cable (which must be yellow- green
and longer than that of the phases) is fixed to the terminal (T fig. 4) marked by the
symbol
. Before starting it working, make sure that the network tension is in compli-
ance with the rated values of the appliance. Please notice in fig. 2 the wiring diagram
of the appliance.
8
Hubungan arus listrik
Untuk kapasitas 10 – 30 L
Kabel listrik (tipe H 05 VV – F 3 x 1 diameter 8,5 mm) dimasukkan kedalam lubang
F sesuai gambar 3 yang terdapat di belakang unit, kemudian dorong kabel hingga
mencapai slot V gambar 4 dekat thermostat.
Untuk memutuskan hubungan listrik dari jaringan, gunakan sakelar bipolar yang
sesuai dengan stardar CEI-EN (bukaan kontak sakelar sedikitnya 3 mm), lebih
baik dilengkapi dengan sekering). Kabel listrik kemudian disambung ke
penjepit (M gambar 4).
Pemanas air harus terhubung ke tanah (arde) dan kabel tanah (biasanya
berwarna kuning hijau dan lebih panjang dari kabel lainnya) dihubungkan ke
terminal ( T gambar 4) ditunjukkan dengan symbol
Sebelum mulai bekerja, pastikan agar tegangan jaringan listrik telah sesuai dengan
nilai pada pemanas air tersebut.
Perhatikan gambar 2 pada diagram kelistrikan pemanas air.
Jika pemanas air tidak dilengkapi dengan kabel listrik, pemanas air tersebut
dapat dihubungkan ke terminal utama dengan kabel tetap dan pipa yang
kokoh.
Menjalankan dan melakukan pengujian
Sebelum unit pemanas air dihubungkan ke sumber daya listrik, isi pemanas dengan
air dari pipa saluran air dingin, yakni dengan membuka kran utama air panas hingga
tangki pemanas air tidak lagi mengandung udara.
Periksa kebocoran air, flensa dan bila perlu kencangkan secara perlahan. Jika
menggunakan model dengan flensa yang dapat mengunci secara otomatis,
pastikan agar flensa tepat berada di tengah; terakhir kencangkan dengan mur yang
dipasang di tengah penahan flensa.
Untuk menghidupkan pemanas air, tekan sakelar. Untuk tipe model yang tidak di
lengkapi dengan saklar, pengoperasian unit dengan cara memutar kenob kontrol
berlawanan arah jarum jam.
Mengatur temperatur pengoperasian.
Untuk model tanpa knob pengatur temperatur, thermostat di setel ke posisi maksi-
mum; jika anda ingin menurunkan temperatur untuk menghemat listrik, lepaskan
unit dari sumber listrik, buka penutup, kemudian putarknob thermostat perlahan-
lahan dengan obeng sesuai dengan tanda +/– yang terdapat pada knob.
Petunjuk pemeliharaan
Semua tindakan perbaikan dan pemeliharaan harus dilakukan oleh teknisi yang
berpengalaman. Sebelum menghubungi Pusat Servis, periksa apakah gangguan
tersebut disebabkan oleh kebocoran air atau masalah daya listrik.
Mengganti komponen
Pertama-tama lepaskan pemanas air dari sumber listrik.
Untuk mengganti komponen listrik, lepaskan alat penutup pada unit.
Untuk mengganti thermostat, putuskan hubunganlistrik dari sumbernya,
kemudian lepaskan thermostat dari dudukannya.
Untuk mengganti elemen pemanas dan anoda, terlebih dahulu kosongkan tangki
pemanas air. Tutup stop kran utama, buka saluran pembuangan pada katup
pengaman dan untuk mengosongkan pipa saluran Inlet, buka kran air panas.
ID
.
17