Ariston 30 FF Panduan Produk - Halaman 8

Jelajahi secara online atau unduh pdf Panduan Produk untuk Ketel uap Ariston 30 FF. Ariston 30 FF 48 halaman. Clas b

Ariston 30 FF Panduan Produk
1.3

ADVANTAGES FOR SERVICE TECHNICIANS

The CLAS B boiler is easy to maintain. Thanks to frontal access for all components, the boiler is able to offer
reduced maintenance times and most of the work can be performed without using tools.
The two "stratification" storages ensure high performaces for long time and don't need any maintenance
work due to deposit of limestone on internal parts.
Furthermore, when an operating anomaly occurs, the display shows the corresponding error code which may
then be relayed to the Assistance Service so that the technician is well prepared with the necessary material
when coming to repair the appliance.
1.3.1

Main advantages for the service Technicians

a. All components may are accessible from the front;
b. Maintenance times are reduced;
c. Maintenance work can be performed, on most of the components inside the boiler, without the use of
tools;
d. Contact temperature sensors;
e. Multifunctional interface with digital display:
Display Central Heating / Domestic Hot Water mode and set temperatura;
Display of error codes;
Reading of the system pressure trough "pressure gauge";
Predisposition for a built-in timer;
Program buttons.
Modulating circulation pump which varies its speed depending to the request flow temperature;
f.
g. Modulating D.H.W. pump which varies its speed depending to the tapping and the storage temperature;
h. Automatic bypass;
Anti-freeze protection system for the Central Heating and Domestic Hot Water circuits;
i.
Limescale protection;
j.
k. Circulation pump and tree way valve anti-sticking system;
"AIR PURGE" function facilitates the elimination of any air bubbles present in the heating circuit;
l.
m. CHIMENEY SWEEP fuction enables flkue gas analysis;
n. Inspection points for flue gas analysis accessible from outside;
o. Air pressure signal accessible from outside;
p. Heating return filter;
q. Domestic cold water inlet filter;
Heating system drain tap;
r.
s. Storages draining taps.
Pag. 8 di 48