Aeotec Smart Switch 6 Manual - Halaman 4

Jelajahi secara online atau unduh pdf Manual untuk Beralih Aeotec Smart Switch 6. Aeotec Smart Switch 6 7 halaman.
Juga untuk Aeotec Smart Switch 6: Panduan Pengguna (12 halaman)

Size: 1 Byte, Default Value: 50
Setting
0 - 100
Parameter 90: Enable/Disable the function of parameter 91 and 92.
This parameter is used to Enable/Disable the function of parameter 91 and 92.
Size: 1 Byte, Default Value: 1
Setting
0
1
Parameter 91: Induce an automatic report
This parameter is used to induce an automatic report when the change of the current power is more/less than the threshold in wattage.
Size: 2 Byte, Default Value: 25
Setting
0 - 32767
Parameter 92: Induce an automatic report
This parameter is used to induce an automatic report when the change of the current power is more/less than the threshold in percentage.
Size: 1 Byte, Default Value: 5
Setting
0 - 100
Parameter 100: Reset Parameter 101 - 103
Size: 1 Byte, Default Value: 0
Setting
1
Parameter 101: To set which report need to be sent.
This parameter is used to configure which reports need to be sent in Report Group 1.The values corresponding to the first four bits of the parameter value
may be combined to create different combinations of reports that you wish to have sent. For example, instantaneous Current is the value 2 and
instantaneous Watts is the value 4, so setting parameter 101 to a value of 6 will result in both instantaneous Current and instantaneous Watts to be
reported. See the full description of the parameter values for other possible settings.
Size: 4 Byte, Default Value: 4
Setting
1
2
4
8
Parameter 102: To set which report need to be sent.
This parameter is used to configure which reports need to be sent in Report Group 2.The values corresponding to the first four bits of the parameter value
may be combined to create different combinations of reports that you wish to have sent. For example, instantaneous Current is the value 2 and
instantaneous Watts is the value 4, so setting parameter 102 to a value of 6 will result in both instantaneous Current and instantaneous Watts to be
reported. See the full description of the parameter values for other possible settings.
Size: 4 Byte, Default Value: 8
Setting
1
2
4
8
Parameter 103: To set which report need to be sent.
This parameter is used to configure which reports need to be sent in Report Group 3.The values corresponding to the first four bits of the parameter value
may be combined to create different combinations of reports that you wish to have sent. For example, instantaneous Current is the value 2 and
instantaneous Watts is the value 4, so setting parameter 103 to a value of 6 will result in both instantaneous Current and instantaneous Watts to be
reported. See the full description of the parameter values for other possible settings.
Description
Brightness level range is 0 to 100%.
Description
Configuration Parameters 91 and 92 are Disabled
Configuration Parameters 91 and 92 are Enabled
Description
The threshold can be set from 0 to 32767 watt.
Description
The threshold can be set from 0 to 100 percent.
Description
Reset Parameter 101-103
Description
Report Instantaneous Voltage
Report Instantaneous Current (Amperes)
Report Instantaneous Watts
Report Accumulated kWh
Description
Report Instantaneous Voltage
Report Instantaneous Current (Amperes)
Report Instantaneous Watts
Report Accumulated kWh