Ariston ACO 32 MFFI Petunjuk Pemasangan dan Servis - Halaman 29
Jelajahi secara online atau unduh pdf Petunjuk Pemasangan dan Servis untuk Ketel uap Ariston ACO 32 MFFI. Ariston ACO 32 MFFI 49 halaman. Aco series
F
. 3.11
IG
F
. 3.12
IG
F
. 3.13
IG
F
. 3.14
IG
F
. 3.15
IG
kW
25
20
15
10
5
0
Soft light adjustment 1 1
The soft light can be adjusted between the maximum power
(shown on the display as "00", i.e. 100%) and the minimum
power (shown on the display as "01", i.e. 1%). The boiler is
factory set to a value which is suitable for the ignition with any
type of gas (approx. 33%).
The value set expressed as a percentage, can be displayed and
adjusted as indicated in Section 3.6.1 (parameter 1)
Maximun Heating Power adjustment 2 2
The maximum heating power can be adjusted to between the
maximum power allowed by the boiler (24kW) and the minimum
power (8kW). The value is factory set to 70% of the maximum
power.
The value set (expressed as a percentage) canbe displayed and
modified as illustrated in Section 3.6.1 (parameter 2).
The display shows the value between 100% ("00" on the display)
and 1% ("01") of this interval.
Display
Ignition Delay adjustment
The ignition delay can be adjusted to between 0 and 7
minutes. The delay is factory set to 2 minutes.
The value set can be displayed and modified as illustrated in
Section 3.6.1 (parameter 3)
Maximun Central Heating temperature
This parameter allows the setting of the maximum temperature for
the central heating circuit. The value is factory set at 82°C and
can be adjusted as illustrated in Section 3.6.1 (parameter 4).
Minimum Central Heating temperature
This parameter allows the setting of the minimum temperature for
the central heating circuit. The value is factory set at 42°C and
can be adjusted as illustrated in Section 3.6.1 (parameter 5).
%
3 3
4 4
5 5
29