Ariston Contract STI 300 indirect Panduan Petunjuk Instalasi - Halaman 9

Jelajahi secara online atau unduh pdf Panduan Petunjuk Instalasi untuk Ketel uap Ariston Contract STI 300 indirect. Ariston Contract STI 300 indirect 20 halaman. Unvented hot water storage cylinders
Juga untuk Ariston Contract STI 300 indirect: Petunjuk Untuk Manual Instalasi (24 halaman)

Ariston Contract STI 300 indirect Panduan Petunjuk Instalasi
C
S
OAXIAL
YSTEMS
F
. 2.9
IG
Exhaust
Type
10 RFFI
Coaxial
C12 (xx)
C32 (xx)
Systems
C42 (xx)
ø 60/100
2.10 R
T
OOM
HERMOSTAT
C
ONNECTION
To connect a room thermostat and/or time clock, it is necessary
to:
1. - Open the control panel as indicated in section 4.3;
2.- Remove screws "A" and remove the inspection cover from
the reverse of the control panel;
3. - For the room-thermostat connect the thermostat switching
wires to the position 5 and 6 and remove the wire link (for
three-wire thermostats connect the neutral to terminal N);
4. - For the time clock connect the clock switching wires to the
positions 3 and 4 and connect the clock motor electrical
supply to the terminals marked L and N.
Note:
A frost thermostat is built-in to the appliance.
For connection to control systems with zone valves
for hot water cylinders see section 3.
Supplied By www.heating spares.co Tel. 0161 620 6677
Maximum
Restrictor
Extension
ø 44 mm
Exhaust/Air
L min = 0.5 m
L = 5 m
L max = 1 m
Risk of Condensation Forming
Piping not insulated
ø 44
ø 44
restrictor
NO restrictor
NONE
NONE
9
I
!
MPORTANT
For all flue systems, a restrictor must
always be inserted into the boiler's
flue connector; the restrictor must be
Ø 44 in diameter depending on the
length of piping indicated in T
2.1.
F
2.9 and F
2.10 illustrate some of
IG
IG
the various designs for coaxial or twin
pipe flue systems.
For
fur ther
infor mation
discharge/ventilation accessories, see
the F
P
A
LUE
IPE
CCESSORIES
Piping insulated
restrictor
NO restrictor
NONE
NONE
A
ABLE
on
M
.
ANUAL
T
2.1
ABLE