Ariston E-Combi 30 Panduan Pengguna - Halaman 7

Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Ketel uap Ariston E-Combi 30. Ariston E-Combi 30 8 halaman. Gas fired condensing wall hung combination boilers
Juga untuk Ariston E-Combi 30: Panduan Pengguna (8 halaman)

Ariston E-Combi 30 Panduan Pengguna
Table summarising error codes
Green Leds
Temperature indicator
40
50
60
70
80

Anti-frost Device.

When the electrical supply is turned on, the anti-frost function acts
on the central heating fl ow temperature probe, independently from
other safety devices.
If the primary circuit temperature is between 3°C and 8°C the
pump will run (with the diverter valve switching between central
heating and hot water every 1 minute) until the temperature
reaches > 9°C.
If the fl ow temperature remains between 3°C and 8°C the pump will
continue to run for a maximum of 20 minutes unless a temperature
above > 9°C is detected in the central heating fl ow, after this the
burner will fi re (heating position) until a temperature of > 30°C is
detected.
If the central heating fl ow temperature is < 3°C, the burner will fi re
(heating position) at minimum power until the temperature reaches
> 30°C, the burner will go out.
If lockout is caused by overheat the burner will not fi re but the pump
will continue to run (heating position).
The anti-frost device activates only when (with the boiler operating
correctly):
- the system pressure is correct;
- the boiler is electrically powered;
- there is a supply of gas.
Reset
90
yellow
red
X
X
X
X
X
X
X
X
Description
Overheat
Insuffi cient circulation
Insuffi cient water (request fi lling)
C.H. Flow temp. probe circuit open / short circuit
C.H. Return temp. probe circuit open / short circuit
External sensor circuit open / short circuit
Floor thermostat contact open
Heating delivery probe problem
Insuffi cient circulation
EEPROM error
Communication error
Too many (> 5) resets in 15 minutes
Main P.C.B. error
Room sensor circuit open / short circuit
No fl ame detected
Flame detected with gas valve closed
Flame lift
1st Ignition Failed
2nd Ignition Failed
Flame cut-off
Thermofuse open
Fan speed error
Change of gas type
Our boilers are designed to function either with Natural Gas (meth-
ane) or L.P.G. gas. If you need to change from one gas to the other,
one of our Authorised Service Centres must be contacted to convert
the appliance.

Maintenance

Schedule an annual maintenance check-up for the boiler with a com-
petent person.
Correct maintenance generally results in savings in the cost of run-
ning the system.
Failure to arrange an annual service for the appliance will invalidate
the second year of the manufacturer's guarantee.
Note
❍ = flashing light
● = lit
User Manual
7