USEFUL INFORMATION AND
TROUBLESHOOTING
BOILER SHUTDOWN
The boiler unit is equipped with safety devices which intervene in certain
situations to shutdown the boiler.
Some of these situations are signalled by the unit and can be corrected by
the user.
SHUTDOWN DUE TO THE FAILURE OF THE
BURNER TO LIGHT AUTOMATICALLY
This anomaly is indicated by the red "B" L.E.D.
To reset the unit, press and then release the "A" button.
At this point, the electronic ignition system will attempt
to light the burner again.
If lighting failure occurs repeatedly, it is recommended
that you contact one of our Authorised Service Centres.
B003
SHUTDOWN DUE TO OVERHEATING
This anomaly is signalled by the red "G" L.E.D.
The boiler shuts off because the safety thermostat
detected that the boiler temperature has reached
the temperature limit.
To reset the unit, wait until the boiler has cooled
and then press the "A" button.
If the safety thermostat shuts off the unit on a
frequent basis, contact one of our Authorised
Service Centres for assistance.
B
A
G
A