B005
Supplied By www.heating spares.co Tel. 0161 620 6677
Q1
Fig. 1.28
R1
R1
Fig. 1.29
Removing the spark generator (SIT Tandem gas
valve)
1. Disconnect ignition leads "Q1" by pulling upwards
(see fig. 1.28) ;
2. Remove the screws "R1" (see fig. 1.29) with a Pozidrive
No. 2 star tip screwdriver;
3. Remove the spark generator.
Fig. 1.30
13