Ariston micro Genius 27 MFFI Petunjuk Servis - Halaman 9

Jelajahi secara online atau unduh pdf Petunjuk Servis untuk Ketel uap Ariston micro Genius 27 MFFI. Ariston micro Genius 27 MFFI 28 halaman. Type c boilers

Ariston micro Genius 27 MFFI Petunjuk Servis
Regulating the heating power for
natural gas (G20)
Regulating the heating power for
butane gas (G30)
Regulating the heating power for
propane gas (G31)
T
"A"
ABLE
B063
model 23
model 27
model 23
model 27
40
38
36
34
model 23
model 27
2.01 Kg/h
2.70
1.16
0.87 Kg/h
20
28 mbar
27.7 mbar
11.0
2.0
6.0 mbar
12 x 0.77
3.15
2.34 Kg/h
1.26
0.94 Kg/h
20
28 mbar
27.7 mbar
11.0
1.6
4.6 mbar
14 x 1.30
14 x 0.77
2.00 Kg/h
0.85 Kg/h
37 mbar
35.5 mbar
7.3 mbar
12 x 0.77
2.31 Kg/h
0.93 Kg/h
37 mbar
35.5 mbar
6.0 mbar
14 x 0.77
CG007A
CG008A
CG009A
TB012A
9