Ariston MICROCOMBI 23 MFFI Petunjuk Servis - Halaman 10

Jelajahi secara online atau unduh pdf Petunjuk Servis untuk Ketel uap Ariston MICROCOMBI 23 MFFI. Ariston MICROCOMBI 23 MFFI 28 halaman. Wall-hung electronic ignition gas combination boiler ariston microcombi 23 mffi/ microcombi 27 mffi
Juga untuk Ariston MICROCOMBI 23 MFFI: Panduan Pengguna (20 halaman), Panduan Petunjuk Instalasi (25 halaman), Panduan Pengguna Akhir (8 halaman), Manual (4 halaman)

Ariston MICROCOMBI 23 MFFI Petunjuk Servis
Soft-light
Adjustment
NB.: It may be necessary to reset the flame failure reset
a number of times during this operation.
10. Remove the pipe from the pressure gauge and connect
screw "C" to the pressure test point in order to seal off
the gas.
11. Carefully check the pressure test points for gas leaks
(valve inlet and outlet).
IMPORTANT!
Whenever you disassemble and reassemble the gas
connections, always check for leaks using a soap and water
solution.
10
Max Heating
Adjustment

1.4.2 Removing the spark generator

1. Disconnect ignition leads "S" by pulling upward
(F
. 1.27);
IG
2. Remove the screw "T" (F
3. Remove the spark generator by pulling forward from the
gas valve (F
. 1.29).
IG
. 1.28);
IG
S
F
. 1.27
IG
T
F
. 1.28
IG
F
. 1.29
IG