Ariston microGENUS 27 MFFI Petunjuk Servis - Halaman 15

Jelajahi secara online atau unduh pdf Petunjuk Servis untuk Ketel uap Ariston microGENUS 27 MFFI. Ariston microGENUS 27 MFFI 28 halaman. Type c boilers
Juga untuk Ariston microGENUS 27 MFFI: Panduan Petunjuk Instalasi (25 halaman), Panduan Pengguna (24 halaman), Petunjuk Servis (28 halaman)

Ariston microGENUS 27 MFFI Petunjuk Servis

Removing the overheat thermostat

1. Disconnect
the
overheat
connections "N1" (F
IG
2. Then remove the thermostat from its mounting by
releasing the securing clip (F
80.eps
83.eps

Removing the heating temperature sensor (N.T.C.)

1. Pull off the electrical connector "P1" and unscrew the
sensor probe using a suitable spanner (F
F
. 1.56
IG
B063
thermostat
. 1.54);
. 1.55).
IG
N1
F
IG
F
IG
. 1.56).
IG
P1
87.eps

Removing the D.H.W. temperature sensor (N.T.C.)

electrical
1. Pull off the electrical connector "Q1" and unscrew the
sensor probe using a suitable spanner (F
60.eps

Removing the divertor valve actuator

. 1.54
1. Unplug the electrical connector "R1" (F
2. Release the retaining clip "S1" and remove the divertor
valve actuator.
. 1.55
74.eps

Removing the D.H.W. flow switch

1. Unplug the electrical connector "T1" (F
2. Release the retaining clip "V1" and remove the D.H.W.
flow switch.
30.eps
Q1
S1
V1
T1
. 1.57).
IG
F
. 1.57
IG
. 1.58);
IG
R1
F
. 1.58
IG
. 1.59);
IG
F
. 1.59
IG
15