Ariston microSYSTEM 21 RFFI Panduan Petunjuk Instalasi - Halaman 12

Jelajahi secara online atau unduh pdf Panduan Petunjuk Instalasi untuk Ketel uap Ariston microSYSTEM 21 RFFI. Ariston microSYSTEM 21 RFFI 48 halaman. Microsystem
Juga untuk Ariston microSYSTEM 21 RFFI: Panduan Pengguna (16 halaman), Panduan Petunjuk Instalasi (24 halaman)

Ariston microSYSTEM 21 RFFI Panduan Petunjuk Instalasi
2.10 R
T
OOM
HERMOSTAT
C
ONNECTION
To connect a room thermostat and/or time clock, it is necessary to:
1. - Open the control panel as indicated in section 4.3;
2.- Remove screws "A" and remove the inspection cover from the reverse of the control
panel;
3. - For the room-thermostat connect the thermostat switching wires to the position 5 and
6 and remove the wire link (for three-wire thermostats connect the neutral to terminal
N);
4. - For the time clock connect the clock switching wires to the positions 3 and 4 and
connect the clock motor electrical supply to the terminals marked L and N.
Note: A frost thermostat is built-in to the appliance.
For connection to control systems with zone valves for hot water cylinders
see section 3.
A
12