F
. 1.0
IG
IN016A
5 - If called for by point. 3, dismantling and cleaning of the combustion
chamber.
6 - If called for by point. 4, dismantling and cleaning of the burner jets.
7 - Visual check of the primary heat exchanger:
-
check for overheating in the blade assembly;
-
clean the exhaust fan if needed.
8 - Adjustment of the flow rate of the gas: flow rate for lighting, partial load and
full load.
9 - Check of the heating safety systems:
-
safety device for maximum temperature (overheat thermostat);
-
safety device for maximum pressure (safety valve).
10- Check of the gas safety systems:
-
safety device for lack of gas or flame ionisation (detection electrode);
-
safety device for gas cock.
11- Check of the electrical connection (make sure it complies with the instructions
in the manual).
12- Check of domestic hot water production efficiency (flow rate and temperature)
13- General check of the combustion by-products of the discharge/ventilation
system.
14- Check of the general performance of the unit.
4
1.2
O
V
VERALL
IEW
L
:
EGEND
1.
Flue connector
2.
Air intake for twin pipe flue systems
3.
Fan
4.
Combustion chamber hood
5.
"Twin-pass" heat exchanger
6.
Domestic hot water temperature probe
7.
Combustion chamber
8.
Combustion chamber insulation panel
9.
Burner
10.
Detection electrode
11.
Ignition electrodes
12.
Gas valve
13.
Spark generator
14.
Pump pressure switch
15.
Safety valve (3 bar)
16.
Automatic By-pass
17.
D.H.W. Flow switch
18.
Domestic hot water inlet filter
19.
Circulation pump with automatic air release valve
20.
Safety thermostat
21.
Main circuit temperature probe
22.
Expansion vessel
23.
Air pressure switch
24.
Combustion analysis points