Whirlpool 4322658A Manual - Halaman 36

Jelajahi secara online atau unduh pdf Manual untuk Kulkas Whirlpool 4322658A. Whirlpool 4322658A 48 halaman. In-door ice system

WARNING
Electrical Shock Hazard
Voltage is present during these tests.
CHECKING THE MOTOR
To check voltages* at the motor for crushed
or cubed ice operation:
1.
Open the freezer door and remove the ice
bucket from the door.
2.
Tape the door switch closed.
* Voltage readings may vary, depending on the supply
voltage, and the type of test equipment being used.
NOTE: When you are instructed to make a
reading at the motor connector, press the tips
of the red and black test leads into the indi-
cated harness connector slots so they touch
the bare metal wire connectors. Reach around
the front of the door and press the ice dispenser
lever to activate the dispenser switch.
Door Switch
Taped Closed
5-12
Pin 1
Test Leads
Press The Ice
Dispenser Lever
Motor Harness
Connector
Press Tips Into
Connector Slots
Against Bare Wire
Terminals To Check
Voltages