Ariston ASL75CXSNA Manual Perbaikan
11. CONTROL BOARD & EEPROM
TECH NOTE 2
REPAIR MANUAL
• To remove the Control Panel (Fig. 11-1), first remove the
Right Side Panel (see Section 10, page 8).
• Next, open the Front Lower Access Door and remove the two
Control Board mounting Phillips screws (Fig.11-2 & Fig.11-3).
• Remove each wiring connector, making sure to note each
wire and wiring connector location.
TECH NOTE 1: The access cap on the control board WILL NOT
have to be removed to remove the Control Board (Fig. 11-3).
Fig. 11-1
TECH NOTE 1
Fig. 11-2
TECH NOTE 2: When replacing the Control Board you must
also replace the EEPROM Chip. When ordering the replace-
ment Control Board make sure to also order the correct
EEPROM Chip for the Model being serviced (Fig. 11-4).
When installing the new EEPROM Chip make sure that
both the Chip Cut Out and the Chip Receptacle Cut Out
are aligned in the same direction (Fig. 11-5).
Fig. 11-4
ASL75CXS NA
Fig. 11-5
Fig. 11-3