Whirlpool WGD4900XW Panduan Petunjuk Instalasi - Halaman 6
Jelajahi secara online atau unduh pdf Panduan Petunjuk Instalasi untuk Pengering Whirlpool WGD4900XW. Whirlpool WGD4900XW 48 halaman. 29" and 27" wide models
Juga untuk Whirlpool WGD4900XW: Buku Petunjuk (8 halaman), Panduan Penggunaan dan Perawatan (28 halaman)
Installation clearances:
The location must be large enough to allow the dryer door to open fully.
Most installations require a minimum 5½" (140 mm) clearance behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."
29" Wide Models
Dryer Dimensions
A. Large opening side-swing door
B. Large opening side-swing door
C. Wide opening side-swing door
D. Wide opening hamper door
Installation Spacing
18"*
(457 mm)
1"
29"
1"
(25 mm)
(737 mm)
(25 mm)
(25 mm)
A
A. Recessed area
B. Side view – closet or confined area
C. Closet door with vents
*Required spacing
Mobile home – Additional installation requirements
This dryer is suitable for mobile home installations. The
installation must conform to the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280) or the Canadian
Manufactured Home Standard CAN/CSA-Z240 MH.
6
14" max.*
48 in.
2
*
(356 mm)
2
(310 cm )
*
24 in.
2
2
(155 cm )
27
1"*
¾"
(705 mm)
B
C
27" Wide Models
Dryer Dimensions
43 "
(1092 mm)
*29
/
"
1
2
(749 mm)
(687 mm)
A
Installation Spacing
18"*
(457 mm)
1"
27"
(25 mm)
(686 mm)
A
3"*
(76 mm)
*Required spacing
Installation spacing for recessed area or closet
The dimensions shown are for the minimum spacing allowed.
Additional spacing should be considered for ease of
■
3"*
installation and servicing.
(76 mm)
Additional clearances might be required for wall, door, and
■
floor moldings.
Additional spacing of 1" (25 mm) on all sides of the dryer is
■
recommended to reduce noise transfer.
For closet installation, with a door, minimum ventilation
■
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Companion appliance spacing should also be considered.
■
Metal exhaust system hardware, available for purchase.
■
For further information, please reference the "Assistance or
Service" section of the Use and Care Guide.
Special provisions must be made in mobile homes to
■
introduce outside air into the dryer. The opening (such as a
nearby window) should be at least twice as large as the dryer
exhaust opening.
23¾"
(603 mm)
43"
(1092 mm)
*29
1
/
"
2
(749 mm)
27"
A. Large opening side-swing door
B. Wide opening hamper door
14" max.*
2
48 in.
*
(356 mm)
2
(310 cm )
*
2
24 in.
2
(155 cm )
1"
1"*
29
5
¼"
½"*
(25 mm)
(25 mm)
(743 mm)
(140 mm)
B
A. Recessed area
B. Side view – closet or confined area
C. Closet door with vents
13¾"
(349 mm)
27"
(687 mm)
B
3"*
(76 mm)
3"*
(76 mm)
C